Alaska

Alaska has no statewide residential building code. The Department of Public Safety's Division of Fire and Life Safety (the State Fire Marshal) is the state building official for commercial buildings and residential buildings of four or more units, adopting the 2021 IBC, IEBC, IMC, IFC and parts of the IFGC in 13 AAC 50 (effective October 28, 2022), and it defers plan review to 12 local jurisdictions such as Anchorage, Fairbanks and Juneau. The Department of Labor and Workforce Development's Mechanical Inspection section adopts the plumbing, electrical, elevator, boiler and pool codes, and the Alaska Housing Finance Corporation's Building Energy Efficiency Standard applies to homes bought with state financing.

15 codes are in force here, 13 of them checked at the source, and this page was last updated November 19, 2026.

Codes in force

Building2021 International Building Code as adopted and amended in 13 AAC 50.020

Applies toAll occupancies and buildings, reviewed by the State Fire Marshal before construction for fire and life safety, except residential housing of three units or fewer. Chapters 1 to 12, 14 to 28 and 30 to 35 and Appendix C are adopted; Chapter 13 (energy) and Chapter 29 (plumbing) are not. Deferred local jurisdictions do their own review.

Based on, and how far it reachesIBC, 2021 edition.A minimum across the state that local governments may add to.

Local changesReferences to the NEC are replaced by the state electrical code (8 AAC 70.025) and references to the International Plumbing and Fuel Gas Codes by the state plumbing code (8 AAC 63.010), except IFGC Section 304 and Chapters 6 and 7. References to the IECC, IPMC, IPSDC, IRC and IWUIC are deleted. The state adds that NFIP compliance under 44 CFR 59 and 60 is the responsibility of the building owner or design professional. Fire Marshal review does not cover structural design or general accessibility beyond fire and life safety.

NextThe 2024 edition IBC. No rulemaking to adopt the 2024 codes was found.

Adopted byDepartment of Public Safety, Division of Fire and Life Safety (State Fire Marshal); deferred local jurisdictions.In force since October 28, 2022.

HousesHouses: no statewide residential code

Applies toOne- and two-family dwellings and triplexes are exempt from State Fire Marshal plan review, and the state code deletes IRC references; houses are regulated only where a city or borough adopts a residential code (Anchorage, Fairbanks, Juneau and others) and, for energy, where state financing triggers the AHFC standard.

Based on, and how far it reachesIRC; the edition varies by city.Each city or county chooses whether to adopt it, and which edition.

Adopted byCities and boroughs that adopt building codes.

Existing buildings2021 International Existing Building Code as adopted in 13 AAC 50.021

Applies toRepair, alteration, addition and change of occupancy of existing buildings under the Fire Marshal's jurisdiction. Chapters 1 to 16 and Appendices A to C are adopted.

Based on, and how far it reachesIEBC, 2021 edition.A minimum across the state that local governments may add to.

Local changesSame substitutions as the IBC for electrical, plumbing and fuel gas references; references to the IECC, IPMC and IRC deleted.

Adopted byState Fire Marshal.In force since October 28, 2022.

Energy, housesAlaska Housing Building Energy Efficiency Standard (BEES)

Applies toHomes whose construction began on or after January 1, 1992 must meet BEES if an AHFC or other state-assisted loan is used to buy them. BEES is the 2018 IECC and ASHRAE 62.2-2016 with Alaska amendments, and requires at least a 5 Star energy rating. DOE lists Alaska as home rule with voluntary enforcement.

Based on, and how far it reachesIECC, 2018 edition.Applies across the state to some buildings only, such as public buildings, schools and hospitals.

Local changesAlaska-specific amendments to the 2018 IECC and ASHRAE 62.2. Compliance is shown on forms PUR-101 (completed only by an Alaska Housing Energy Rater) and PUR-102, or a certificate of occupancy from an AHFC-approved municipality.

Adopted byAlaska Housing Finance Corporation (15 AAC 155).

Energy, other buildingsCommercial energy: no statewide code (AHFC BEES for state-funded programs)

Applies toIBC Chapter 13 is not adopted, so commercial buildings have no statewide energy code. AHFC's BEES (2018 IECC with Alaska amendments) covers commercial work in AHFC-funded programs and energy retrofits of public buildings; DOE lists commercial enforcement as voluntary.

Based on, and how far it reachesIECC, 2018 edition.Applies across the state to some buildings only, such as public buildings, schools and hospitals.

Adopted byAlaska Housing Finance Corporation; local governments.

Fire2021 International Fire Code as adopted and amended in 13 AAC 50.025

Applies toAll occupancies and buildings, for hazards of fire and explosion. Chapters 1 to 12, 20 to 40, 50 to 67 and 80 and Appendices B to I, K, L and N are adopted; Chapters 13 to 19, 41 to 49 and 68 to 79 are reserved.

Based on, and how far it reachesIFC, 2021 edition.A minimum across the state that local governments may add to.

Local changesAlaska amendments include relief for remote fuel tank facilities (tank support fireproofing near permafrost, open vents in cold climate locations) and fire alarm, sprinkler permit and plan review rules (13 AAC 50.030, 50.035, 50.027).

Adopted byState Fire Marshal; deferred local fire departments.In force since October 28, 2022.

Plumbing2018 Uniform Plumbing Code (8 AAC 63)

Applies toNew and altered plumbing, gas and fuel piping. The state's Mechanical Inspection section has plumbing jurisdiction in communities of 2,500 people or more; Anchorage inspects under a memorandum of agreement. A state certificate of fitness is required to do plumbing work outside small communities.

Based on, and how far it reachesUPC, 2018 edition.A minimum across the state that local governments may add to.

Local changesMechanical Inspection lists the adoption as 8 AAC 63.101(1); 13 AAC 50 refers to the plumbing code as adopted by 8 AAC 63.010.

Adopted byDepartment of Labor and Workforce Development, Mechanical Inspection.

Mechanical2021 International Mechanical Code as adopted in 13 AAC 50.023

Applies toMechanical systems in all occupancies and buildings under the Fire Marshal's jurisdiction. Chapters 1 to 15 and Appendix A are adopted.

Based on, and how far it reachesIMC, 2021 edition.A minimum across the state that local governments may add to.

Local changesElectrical references replaced by the state electrical code; fuel gas references limited as in the IBC.

Adopted byState Fire Marshal.In force since October 28, 2022.

Fuel gasParts of the 2021 International Fuel Gas Code (13 AAC 50.024) and the state plumbing code

Applies toIFGC Chapter 3 Section 304 (combustion air) and Chapters 6 and 7 (specific appliances, gaseous hydrogen systems) regulate fuel gas utilization equipment; gas piping otherwise falls under the state plumbing code (UPC).

Based on, and how far it reachesIFGC, 2021 edition.A minimum across the state that local governments may add to.

Local changesIECC and IRC references deleted from IFGC Chapter 1; electrical references replaced.

Adopted byState Fire Marshal; Mechanical Inspection for gas piping.In force since October 28, 2022.

Electrical2020 National Electrical Code (8 AAC 70.025(a)) and 2017 National Electrical Safety Code (8 AAC 70.025(b))

Applies toNew and altered electrical installations. Mechanical Inspection inspects commercial structures and dwellings of three units and above; Anchorage inspects under a memorandum of agreement. A state certificate of fitness is required for work under the NEC everywhere in Alaska.

Based on, and how far it reachesNFPA 70, 2020 edition.A minimum across the state that local governments may add to.

Adopted byDepartment of Labor and Workforce Development, Mechanical Inspection.

AccessibilityIBC Chapter 11 (accessibility) through 13 AAC 50.020

Applies toChapter 11 is among the adopted IBC chapters, but the Fire Marshal's plan review does not address general accessibility beyond what fire and life safety require; the federal ADA applies separately.

Based on, and how far it reachesIBC, 2021 edition.A minimum across the state that local governments may add to.

Adopted byState Fire Marshal (adoption); local jurisdictions.In force since October 28, 2022.

Elevators and escalatorsElevator codes adopted in 8 AAC 77.005

Applies toElevators, escalators, wheelchair lifts and dumbwaiters used by the public: ASME A17.1-2016, A17.3-2011 (existing), A18.1-2017 (platform lifts and chairlifts), A17.2-2017, A17.6-2017 and A17.7-2007. A state certificate of operation is required, with some exemptions; Anchorage inspects and permits within its jurisdiction.

Based on, and how far it reachesASME A17.1, 2016 edition.Applies across the state, and local governments enforce it as written.

Adopted byDepartment of Labor and Workforce Development, Mechanical Inspection.

Pools and spas2018 Uniform Swimming Pool, Spa and Hot Tub Code (8 AAC 63.101(2))

Applies toPlumbing of swimming pools, spas and hot tubs under the state plumbing program; the 2018 Uniform Solar Energy and Hydronics and Geothermal Code is also adopted (8 AAC 63.101(3)).

Based on, and how far it reachesUSPSHTC, 2018 edition.A minimum across the state that local governments may add to.

Adopted byDepartment of Labor and Workforce Development, Mechanical Inspection.

Structural loadsASCE 7-16 through the 2021 IBC

Applies toDesign loads for buildings under the IBC (the 2021 IBC references ASCE 7-16); the Fire Marshal does not review structural design, so local building departments or the design professional carry it.

Based on, and how far it reachesASCE 7, 2016 edition.A minimum across the state that local governments may add to.

Adopted byState Fire Marshal (adoption); local building departments.In force since October 28, 2022.

Boilers and pressure vesselsBoiler and pressure vessel codes (8 AAC 80.010; AS 18.60)

Applies toEvery boiler and pressure vessel in a commercial or public structure must be inspected and hold a state certificate of operation, with some exemptions: 2013 ASME Boiler and Pressure Vessel Code, the 2018 API pressure vessel inspection code, and the current National Board Inspection Code (AS 18.60.315). Commissioned private insurance inspectors also inspect.

Based on, and how far it reachesASME BPVC, 2013 edition.Applies across the state, and local governments enforce it as written.

Adopted byDepartment of Labor and Workforce Development, Mechanical Inspection.

Not adopted here, or not found yet

Life safetyNFPA 101, Life Safety Code (not adopted)No code of this kind is adopted

Applies to13 AAC 50 adopts the IBC and IFC, not NFPA 101. Health care facilities in federal programs follow the CMS-required edition (see the federal page).

Based on, and how far it reachesNFPA 101.

Adopted byNot adopted.

Not yet checked at the source
Green building and stretch codesGreen building codesNo code of this kind is adopted

Applies toNo statewide green building or stretch code was found.

Adopted byNone.

Wildland-urban interfaceWildland-urban interface code (not adopted)No code of this kind is adopted

Applies to13 AAC 50 deletes the IBC's references to the IWUIC; no statewide wildland-urban interface code applies.

Based on, and how far it reachesIWUIC.

Adopted byNone statewide.

Property maintenanceProperty maintenance code (not adopted statewide)No code of this kind is adopted

Applies to13 AAC 50 deletes the IBC and IEBC references to the IPMC; any property maintenance code is local.

Based on, and how far it reachesIPMC.

Adopted byLocal governments.

Sprinkler rules for housesResidential sprinklers (no statewide rule for houses)No code of this kind is adopted

Applies toWith no statewide residential code, sprinklers in one- and two-family dwellings depend on local codes. Where a multipurpose residential sprinkler system is installed, 13 AAC 50.035 lets a plumber with a state certificate of fitness (AS 18.62) who is certified by the system's manufacturer install it to NFPA 13D (2019) or IRC P2904 without a fire systems permit.

Based on, and how far it reachesIRC.

Adopted byLocal governments; State Fire Marshal for fire system permits.

Not yet checked at the source
Manufactured homesManufactured home installationNot found

Applies toNo state manufactured home installation program was found among the codes adopted by the State Fire Marshal or Mechanical Inspection.

Based on, and how far it reachesHUD.

Adopted byNot found.

Modular and factory-built buildingsModular and factory-built buildingsNot found

Applies toNo state modular or factory-built building program was found; such buildings fall under the State Fire Marshal's plan review like site-built buildings when they are commercial or have four or more units (not confirmed).

Based on, and how far it reachesThe state's own code.

Adopted byNot found.

Not yet checked at the source
Flood rules beyond the federal minimumFlood rules beyond the NFIPNo code of this kind is adopted

Applies toNo state flood standard beyond the NFIP was found. The state building code says compliance with the NFIP (44 CFR 59 and 60) is the owner's or design professional's responsibility and points to the Department of Commerce, Community, and Economic Development's floodplain management program; communities that join the NFIP administer it locally.

Based on, and how far it reachesNFIP.

Adopted byCommunities in the NFIP; DCCED Division of Community and Regional Affairs (information).

Not yet checked at the source

Who designs, seals and builds

Architect
The architect, engineer and land surveyor law does not apply to a person preparing drawings for: a building for the person's own use as a single-family residence; farm or ranch buildings unless public health, safety or welfare is involved; a building used only as a residence by not more than four families and not more than two stories high, or by not more than two families and not more than three stories high if it meets any building or residential code the municipality has adopted; a private noncommercial garage, workshop or similar building under 2,000 square feet; and alterations or repairs that do not affect the structural system or safety. Otherwise Alaska-registered professionals must be in responsible charge.AS 08.48.331Checked at the source
Engineer
The same exemptions apply to engineering (AS 08.48.331); all other projects, public or private, that need engineering must use Alaska-registered engineers in responsible charge. Specialty contractors may prepare shop drawings for their own work.AS 08.48.331Checked at the source
Contractor
Contractors and electrical and mechanical administrators are licensed by the Department of Commerce, Community, and Economic Development; the Department of Labor's Mechanical Inspection section enforces contractor licensing statewide under an agreement with Commerce. Electricians and plumbers need state certificates of fitness from the Department of Labor.AS 08.18 (contractors); AS 08.40 (electrical administrators); AS 18.62 (certificates of fitness)Not yet checked at the source

Design loads and hazards

Wind
ASCE 7-16 through the 2021 IBC; Alaska has its own special wind areas and high winds along the coasts (values not confirmed).
Snow
No state snow load map was found; local building departments set ground snow loads, which vary greatly (values not confirmed).
Seismic
Southcentral and southeast Alaska are among the most seismically active areas of the country (values not confirmed).
Frost depth
Deep frost and permafrost in much of the state; local jurisdictions set footing depths. The state fire code allows waivers for remote fuel tank fireproofing where heat could reach permafrost and cause foundation settlement.
Flood
NFIP compliance is the owner's or designer's responsibility; communities in the NFIP administer floodplain rules.
Other hazards
Tsunami and coastal erosion hazards; avalanche areas. Information on mitigating natural hazards, including seismic hazards, is available from the Division of Homeland Security and Emergency Management.

Permits

Who issues them
The State Fire Marshal reviews and approves plans (its approval works as the permit) before construction, repair, remodel, addition, change of occupancy or fuel tank work on any building except housing of three units or fewer. Twelve jurisdictions have deferrals and review plans locally: Anchorage (through both its Fire Department and Building Safety), Palmer, Juneau, Fairbanks, Kenai, Ketchikan, Seward, Kodiak, Sitka, Soldotna, the University of Alaska Fairbanks and the Central Mat-Su Fire Service Area. Electrical, plumbing, elevator and boiler work is inspected by the Department of Labor (Anchorage by agreement).
Review time limits
The Fire Marshal says review typically takes two to four weeks after full payment; no statutory deadline was found. Starting work before approval costs an extra fee equal to the plan review fee.
Private review
No private plan review program was found.

Cities and counties with their own codes

Where to read the codes, and who to ask

Not found yet

  • Effective dates of the 2018 UPC, 2020 NEC, ASME A17.1-2016 and 2013 ASME boiler code adoptions were not found, and the plumbing rule is cited as both 8 AAC 63.101 and 8 AAC 63.010.
  • No sign was found of the State Fire Marshal moving to the 2024 I-codes.
  • Anchorage's AO 2026-033 (re-enacting Title 23, apparently with 2024 codes) and local adoptions in Fairbanks, Juneau and other deferred jurisdictions were not confirmed.
  • Contractor licensing details (AS 08.18 endorsements, residential endorsement) were not confirmed.
  • No state manufactured or modular home program, state snow load data or radon rule was found; wind, snow, seismic and frost values are not confirmed.
  • The effective date of the current BEES (2018 IECC) adoption under 15 AAC 155 was not found.