Iowa's State Building Code (2024 IBC, IRC and IEBC since September 10, 2025) is written by the Department of Inspections, Appeals, and Licensing (DIAL). It applies to state-owned and state-funded buildings, licensed health and care facilities and other listed buildings everywhere, and to other buildings only where a city or county adopts it; cities and counties may adopt their own codes. Some parts apply statewide: the energy code, accessibility rules, the state plumbing and mechanical codes, the electrical code and the state fire code.

20 codes are in force here, 18 of them checked at the source, and this page was last updated November 19, 2026.

Codes in force

BuildingIowa State Building Code, general provisions (481 IAC 301.3)

Applies toBuildings owned by the state, built with state funds, licensed health care, assisted living, residential care and similar facilities, and (unless a local department reviews them) schools, colleges, child care for seven or more, correctional and gaming facilities; elsewhere only where a local jurisdiction adopts it. Detached one- and two-family dwellings and townhouses up to three stories follow the IRC.

Based on, and how far it reachesIBC, 2024 edition.Applies across the state to some buildings only, such as public buildings, schools and hospitals.

Local changesIowa amendments (ARC 9474C); projects started within 12 months of the change may use the previous standards.

Adopted byIowa Department of Inspections, Appeals, and Licensing, State Building Code Bureau.In force since September 10, 2025.

HousesIowa State Building Code, residential construction (481 IAC 301.8)

Applies toDetached one- and two-family dwellings and townhouses up to three stories, where the State Building Code applies (state-funded projects or local adoption).

Based on, and how far it reachesIRC, 2024 edition.Applies across the state to some buildings only, such as public buildings, schools and hospitals.

Local changesDeletes the IRC sprinkler requirements (R309.1 and R309.2); Table R301.2 values are set by project location.

Adopted byIowa Department of Inspections, Appeals, and Licensing.In force since September 10, 2025.

Existing buildingsIowa State Building Code, existing buildings (481 IAC 301.7)

Applies toAlterations, additions and changes of occupancy where the State Building Code applies. A State Historic Building Code (481 IAC 301.42) also exists.

Based on, and how far it reachesIEBC, 2024 edition.Applies across the state to some buildings only, such as public buildings, schools and hospitals.

Adopted byIowa Department of Inspections, Appeals, and Licensing.In force since September 10, 2025.

Energy, housesIowa residential energy code (481 IAC 301.24)

Applies toResidential construction of three or fewer stories throughout the state.

Based on, and how far it reachesIECC, 2012 edition.Applies across the state, and local governments enforce it as written.

Local changesIowa amendments (for example, exterior wall cavities may not be used for return ducts); readopted on the same edition with the 2025 rules.

Adopted byIowa Department of Inspections, Appeals, and Licensing.In force since April 1, 2014.

Energy, other buildingsIowa nonresidential energy code (481 IAC 301.25)

Applies toCommercial construction and residential buildings of four or more stories throughout the state; DOE lists ASHRAE 90.1-2010 as the alternative.

Based on, and how far it reachesIECC, 2012 edition.Applies across the state, and local governments enforce it as written.

Local changesIowa amendments.

Adopted byIowa Department of Inspections, Appeals, and Licensing.In force since April 1, 2014.

FireState fire code (481 IAC chapter 280, Fire Control Administration)

Applies toFire safety in buildings statewide; state inspectors cover state-regulated facilities (schools, jails, day care, residential care, assisted living) and complaints but not one- and two-family dwellings. Fire protection plans for some projects may go to a local fire department under a local fire ordinance recognized by the state.

Based on, and how far it reachesIFC, 2024 edition.Applies across the state, and local governments enforce it as written.

Local changesIowa amendments (ARC 9472C); replaced the former Public Safety chapter 661-201.

Adopted byIowa Department of Inspections, Appeals, and Licensing (State Fire Marshal functions).In force since September 10, 2025.

Life safetyLife Safety Code for federally certified health care facilities

Applies toState fire safety inspectors inspect hospitals, nursing homes, dialysis centers, intermediate care and ambulatory surgical centers for CMS; the state mechanical code defines the Life Safety Code as the 2012 edition.

Based on, and how far it reachesNFPA 101, 2012 edition.Applies across the state to some buildings only, such as public buildings, schools and hospitals.

Adopted byIowa Department of Inspections, Appeals, and Licensing.

PlumbingIowa state plumbing code (481 IAC chapter 425)

Applies toPlumbing in all buildings and premises in Iowa. Local jurisdictions may not adopt other plumbing codes but may adopt stricter amendments if they send copies to the board.

Based on, and how far it reachesUPC, 2024 edition.A minimum across the state that local governments may add to.

Local changesIowa amendments; adopts UPC sections 101 and 102, chapters 2 to 17 and appendices A and M.

Adopted byPlumbing and Mechanical Systems Board (DIAL).In force since March 26, 2025.

MechanicalIowa state mechanical code (481 IAC chapter 426)

Applies toDesign, installation, maintenance, alteration and inspection of permanently installed mechanical systems in buildings and premises in Iowa.

Based on, and how far it reachesIMC, 2024 edition.Applies across the state, and local governments enforce it as written.

Local changesIowa amendments; IFGC references replaced with NFPA 54, NFPA 58, LP gas rules and the state plumbing code.

Adopted byPlumbing and Mechanical Systems Board (DIAL).In force since March 26, 2025.

Fuel gasFuel gas piping under the state plumbing and mechanical codes (481 IAC 425.3, 426.3)

Applies toFuel gas piping follows rule 481 IAC 425.3; the mechanical code points to NFPA 54 and NFPA 58 (current editions) instead of the IFGC; LP gas facilities follow 481 IAC 286.1.

Based on, and how far it reachesNFPA 54, current edition.Applies across the state, and local governments enforce it as written.

Adopted byPlumbing and Mechanical Systems Board (DIAL).In force since March 26, 2025.

ElectricalIowa electrical code: 2023 NEC as set by House File 2800

Applies toAll electrical installations in Iowa. State electrical permits and inspections apply unless a local jurisdiction inspects.

Based on, and how far it reachesNFPA 70, 2023 edition.Applies across the state, and local governments enforce it as written.

Local changesHF2800, signed June 2, 2026, removed the state amendments in 481 IAC 404.3; only the exclusions and amendments written into HF2800 apply to the 2023 NEC until the 2026 NEC is adopted.

NextThe 2026 edition NEC. DIAL says the 2023 NEC stays the minimum until the 2026 NEC is officially adopted; no date found.

Adopted byElectrical Examining Board; Iowa Department of Inspections, Appeals, and Licensing.In force since June 2, 2026.

AccessibilityAccessibility of buildings and facilities available to the public (481 IAC 301.16 to 301.19)

Applies toNew construction of buildings and facilities available to the public (other than places of worship), and renovations where codes require new-construction standards (rule 301.18, based on the 2010 ADA Standards); multiunit residential buildings statewide (rule 301.19, based on the Fair Housing Act).

Based on, and how far it reaches2010 ADA Standards, 2010 edition.Applies across the state, and local governments enforce it as written.

Adopted byIowa Department of Inspections, Appeals, and Licensing.In force since September 10, 2025.

Elevators and escalatorsIowa conveyance rules (481 IAC chapters 371 to 373)

Applies toElevators, escalators, dumbwaiters, lifts and similar equipment under Iowa Code chapter 89A; installations on or after June 1, 2021 follow ASME A17.1-2019/CSA B44-19 (earlier installations follow the edition in force when installed). Equipment must be registered, permitted and inspected by the state or a state-commissioned private inspector.

Based on, and how far it reachesASME A17.1, 2019 edition.Applies across the state, and local governments enforce it as written.

Local changesRule last amended effective February 12, 2025.

Adopted byIowa Department of Inspections, Appeals, and Licensing; Elevator Safety Board.In force since June 1, 2021.

Green building and stretch codesSustainable design standards (State Building Code Part 5)

Applies toSustainable design criteria for residential and commercial projects, reviewed by DIAL for an extra fee; no green code applies to private buildings generally.

Based on, and how far it reachesThe state's own code (481 IAC 301.30 to 301.35).Applies across the state to some buildings only, such as public buildings, schools and hospitals.

Adopted byIowa Department of Inspections, Appeals, and Licensing.In force since September 10, 2025.

Property maintenanceLocal property maintenance codes

Applies toNot part of the State Building Code; cities adopt their own.

Based on, and how far it reachesIPMC; the edition varies by city.Each city or county chooses whether to adopt it, and which edition.

Adopted byCities and counties.

Sprinkler rules for housesIRC sprinkler requirement deleted (481 IAC 301.8(5) and (6))

Applies toWhere the State Building Code applies, new one- and two-family dwellings and townhouses do not need sprinklers: IRC sections R309.1 and R309.2 are deleted.

Based on, and how far it reachesIRC, 2024 edition.Applies across the state to some buildings only, such as public buildings, schools and hospitals.

Adopted byIowa Department of Inspections, Appeals, and Licensing.In force since September 10, 2025.

Manufactured homesManufactured home installation and licensing (DIAL Factory Built Structures)

Applies toManufactured home installers, retailers and manufacturers are licensed by DIAL, and installations carry state installation seals.

Based on, and how far it reachesHUD 24 CFR 3280.Applies across the state, and local governments enforce it as written.

Adopted byIowa Department of Inspections, Appeals, and Licensing.

Checked at the source
Modular and factory-built buildingsModular and factory-built structures (DIAL)

Applies toModular structure manufacturers and third-party inspection agencies are approved by DIAL and units carry modular seals; factory-built structures may meet either the state plumbing code or the 2024 IPC.

Based on, and how far it reachesThe state's own code.Applies across the state, and local governments enforce it as written.

Adopted byIowa Department of Inspections, Appeals, and Licensing.

Structural loadsStructural design under the 2024 IBC; weather safe room standards (481 IAC 301.37, 301.38)

Applies toStructural loads through the 2024 IBC (which references ASCE 7-22) where the State Building Code applies. Storm shelters and weather safe rooms, when built, must meet ICC 500-2014; the rules set design standards but do not themselves require a safe room.

Based on, and how far it reachesASCE 7, 2022 edition.Applies across the state to some buildings only, such as public buildings, schools and hospitals.

Adopted byIowa Department of Inspections, Appeals, and Licensing.In force since September 10, 2025.

Not yet checked at the source
Boilers and pressure vesselsBoiler and pressure vessel rules (481 IAC chapters 390 to 395)

Applies toBoilers and unfired steam pressure vessels under Iowa Code chapter 89: ASME Boiler and Pressure Vessel Code (2021) and National Board Inspection Code (2021); advance notice of installation required.

Based on, and how far it reachesASME BPVC, 2021 edition.Applies across the state, and local governments enforce it as written.

Adopted byIowa Department of Inspections, Appeals, and Licensing, Boiler and Pressure Vessel Safety.In force since March 26, 2025.

Not adopted here, or not found yet

Pools and spasPublic swimming pool and spa rules (Iowa Department of Health and Human Services)Not found

Applies toPublic pools are regulated by the state health agency; the rule chapter and edition are not confirmed. The ISPSC is not adopted statewide.

Based on, and how far it reachesThe state's own code; the edition is not confirmed.

Not confirmed yet: who adopts it.

Not yet checked at the source
Wildland-urban interfaceNo wildland-urban interface codeNo code of this kind is adopted

Applies toNo IWUIC adoption found.

Adopted byIowa Department of Inspections, Appeals, and Licensing.

Flood rules beyond the federal minimumFloodplain rules (Iowa Department of Natural Resources)Not found

Applies toIowa DNR regulates construction in floodplains; the freeboard required is not confirmed.

Based on, and how far it reachesThe state's own code; the edition is not confirmed.

Adopted byIowa Department of Natural Resources.

Not yet checked at the source

Who designs, seals and builds

Architect
DIAL's Iowa Building Code Official's Handbook matrix (September 2019) says an architect and engineer may not be required for: one-story commercial buildings up to 10,000 sq ft; two-story commercial up to 6,000 sq ft; one-story warehouses up to 10,000 sq ft; churches of one or two stories up to 2,000 sq ft; detached residential buildings of up to three stories with 12 or fewer dwelling units; light industrial buildings; and factory-built buildings certified by a professional engineer. Larger buildings and all educational, institutional, industrial, hazardous and assembly buildings require them. Plans submitted to the state must be wet-signed and sealed.Iowa Code chapters 544A and 542B; 481 IAC chapter 300Checked at the source
Engineer
Same matrix: an engineer is required where an architect is, and for hazardous uses; corporate- or publicly owned agricultural facilities such as grain elevators need an engineer. Factory-built buildings of any size may be certified by an Iowa professional engineer.Iowa Code chapter 542BChecked at the source
Contractor
Contractors register with DIAL. Electricians and electrical contractors are licensed by the Electrical Examining Board; plumbing, HVAC, refrigeration, hydronic and sheet metal contractors and workers by the Plumbing and Mechanical Systems Board; manufactured home installers and retailers by DIAL.Iowa Code chapters 91C, 103 and 105Checked at the source

Design loads and hazards

Wind
Through the 2024 IBC and IRC where the State Building Code applies; IRC Table R301.2 values are set by project location.
Snow
Through the 2024 IBC and IRC; no state snow map found.
Seismic
Not confirmed; Iowa is a low seismic hazard area.
Frost depth
Not set by the State Building Code; local values.
Flood
Iowa DNR floodplain rules; freeboard not confirmed.
Other hazards
Weather safe rooms and storm shelters, when built, must meet ICC 500-2014 (481 IAC 301.37 and 301.38).
Not yet checked at the source

Permits

Who issues them
Cities and counties with local building code enforcement (DIAL lists over 120 cities and Bremer, Johnson, Linn, Polk, Pottawattamie and Scott counties) review plans and issue permits. DIAL's Building Code Bureau reviews plans for state-owned and state-funded buildings and licensed health care, assisted living, adult day, residential care and elder group homes regardless of local enforcement, and for schools, colleges, child care, correctional and gaming facilities unless a DIAL-approved local department reviews them. DIAL issues electrical, elevator and boiler permits.
Review time limits
No statutory plan review time limit found.
Private review
Elevator owners may hire a private inspector commissioned by the state; DIAL commissions special boiler inspectors and approves third-party agencies for modular structures.

Cities and counties with their own codes

  • Des Moines

    Local building code enforcement; plan reviews go to the city except projects DIAL must review.

  • Cedar Rapids

    Local building code enforcement.

  • Davenport

    Local building code enforcement.

  • Iowa City

    Local building code enforcement.

Where to read the codes, and who to ask

Not found yet

  • Public pool rules and floodplain freeboard (DNR) are not confirmed.
  • Whether the state requires storm shelters in new schools (beyond the ICC 500 design standard) was not confirmed.
  • Effective dates of the 2012 IECC adoption (April 1, 2014) come from DOE; the rule was readopted in 2025.
  • Local codes adopted by Des Moines, Cedar Rapids, Davenport and other cities with their own enforcement are not confirmed.
  • The architect and engineer matrix is dated September 2019; the statutes behind it (Iowa Code 544A, 542B) were not confirmed.