Massachusetts
Massachusetts has one state building code, 780 CMR (the 10th Edition, based on the 2021 I-codes), adopted by the Board of Building Regulations and Standards and enforced by local building commissioners. Other boards write their own statewide codes: fire and electrical (Board of Fire Prevention Regulations, 527 CMR), plumbing and gas (248 CMR), elevators (524 CMR) and accessibility (521 CMR). The energy code has three levels, and each city or town chooses the base code, the Stretch Code or the Specialized Opt-in Code written by the Department of Energy Resources.
17 codes are in force here, 13 of them checked at the source, and this page was last updated November 19, 2026.
Codes in force
Building780 CMR, Massachusetts State Building Code, 10th Edition (base code)October 11, 2024
Applies toAll buildings and structures in the Commonwealth. The 10th Edition first took effect October 11, 2024 with a concurrency period, extended to June 30, 2025, during which the 9th Edition could still be used; since then it is the only building code in effect.
Based on, and how far it reachesIBC, 2021 edition.Applies across the state, and local governments enforce it as written.
Local changesBuilt on the 35 chapters and appendices of the 2021 IBC, with select chapters replaced by Massachusetts amendments and other I-codes; Chapter 51 is the Massachusetts Residential Code. Massachusetts amends the I-codes significantly; official amendment text is sold by the State House Bookstore and mass.gov posts unofficial copies.
Adopted byBoard of Building Regulations and Standards (Office of Public Safety and Inspections, Division of Occupational Licensure); enforced by local building commissioners and inspectors.In force since October 11, 2024.
Houses780 CMR Chapter 51, Massachusetts Residential Code (10th Edition)October 11, 2024
Applies toOne- and two-family dwellings and townhouses within the IRC scope.
Based on, and how far it reachesIRC, 2021 edition.Applies across the state, and local governments enforce it as written.
Local changesAdopts the 2021 IRC with Massachusetts amendments as a new Chapter 51 of 780 CMR. The concurrency period with the 9th Edition ended June 30, 2025.
Adopted byBoard of Building Regulations and Standards; enforced by local building officials.In force since October 11, 2024.
Existing buildings780 CMR, 10th Edition (2021 International Existing Building Code as amended)October 11, 2024
Applies toRepairs, alterations, additions and changes of occupancy of existing buildings.
Based on, and how far it reachesIEBC, 2021 edition.Applies across the state, and local governments enforce it as written.
Local changesMassachusetts amendments are in 780 CMR.
Adopted byBoard of Building Regulations and Standards.In force since October 11, 2024.
Energy, houses780 CMR Chapter 11R, Massachusetts base energy code (residential)October 11, 2024
Applies toNew houses and low-rise residential buildings in the municipalities that follow the base code. Most municipalities have adopted the Stretch Code or the Specialized Code instead (see the green rows); as of November 18, 2026, 7.32% of residents live in a base code community.
Based on, and how far it reachesIECC, 2021 edition.A minimum across the state that local governments may add to.
Local changesIECC 2021 with Massachusetts amendments.
Adopted byBoard of Building Regulations and Standards (base code); Department of Energy Resources writes the Stretch and Specialized codes.In force since October 11, 2024.
Energy, other buildings780 CMR Chapter 13, Massachusetts base energy code (commercial)October 11, 2024
Applies toCommercial and high-rise residential buildings in municipalities that follow the base code; Stretch and Specialized communities use 225 CMR 23.00 instead.
Based on, and how far it reachesIECC and ASHRAE 90.1 (2021 IECC; ASHRAE 90.1-2019).A minimum across the state that local governments may add to.
Local changesIECC 2021 with Massachusetts amendments; DOE rates the amendments 7.8% more efficient than the model code.
Adopted byBoard of Building Regulations and Standards.In force since October 11, 2024.
Green building and stretch codesMassachusetts Stretch Energy Code (225 CMR 22.00 residential, 225 CMR 23.00 commercial)
Applies toEvery building in a municipality that has adopted it. As of November 18, 2026, 240 municipalities use the Stretch Code (not counting Specialized Code adopters), covering 58.63% of residents. Adoption is required to be a designated Green Community.
Based on, and how far it reachesIECC with Massachusetts amendments, 2021 edition.Each city or county chooses whether to adopt it, and which edition.
Local changesLatest Stretch and Specialized code text is dated February 14, 2025; DOER proposed further revisions in 2026, held a hearing on June 16, 2026 and took comments until June 24, 2026.
NextThe 2021 edition (revised). DOER's 2026 proposed revisions to the Stretch and Specialized codes went through public comment in June 2026; no adoption date was posted.
Adopted byDepartment of Energy Resources (DOER) writes it; city and town meetings or councils adopt it.
Green building and stretch codesMunicipal Opt-in Specialized Energy Code (225 CMR 22.00 with Appendix RC, 225 CMR 23.00 with Appendix CC)
Applies toEvery building in a municipality that has adopted it, aimed at net-zero and electric construction. As of November 18, 2026, 62 municipalities had adopted it (since 2023), covering 34.05% of residents, including Boston, Cambridge, Somerville, Newton, Worcester, Brookline, Lexington and Salem. Adoption is required to be a Climate Leader Community.
Based on, and how far it reachesIECC with Massachusetts amendments, 2021 edition.Each city or county chooses whether to adopt it, and which edition.
Local changesRelief from some electrification requirements is available for qualifying district energy systems (DOER guideline, 2025).
NextThe 2021 edition (revised). Covered by DOER's 2026 proposed revisions; no adoption date was posted.
Adopted byDepartment of Energy Resources writes it; municipalities adopt it.
Fire527 CMR 1.00, Massachusetts Comprehensive Fire Safety CodeDecember 9, 2022
Applies toFire prevention and fire protection in buildings and premises statewide.
Based on, and how far it reachesNFPA 1, 2021 edition.Applies across the state, and local governments enforce it as written.
Local changesNFPA 1 (2021) with Massachusetts amendments; a further amendment package took effect May 12, 2023.
NextA newer edition, not yet named. On October 15, 2026 the Board of Fire Prevention Regulations voted to begin promulgating amendments to 527 CMR 1.00; the proposed text is posted but not adopted.
Adopted byBoard of Fire Prevention Regulations (Department of Fire Services); enforced by local fire departments.In force since December 9, 2022.
Plumbing248 CMR 10.00, Uniform State Plumbing CodeDecember 8, 2023
Applies toAll plumbing work in the Commonwealth, done by plumbers licensed by the Board.
Based on, and how far it reachesThe state's own code, 2023.Applies across the state, and local governments enforce it as written.
Local changesA Massachusetts code written by the Board, not a model plumbing code.
Adopted byBoard of State Examiners of Plumbers and Gas Fitters (Division of Occupational Licensure).In force since December 8, 2023.
Mechanical780 CMR, 10th Edition (2021 International Mechanical Code as amended)October 11, 2024
Applies toHeating, ventilating, air conditioning and refrigeration systems.
Based on, and how far it reachesIMC, 2021 edition.Applies across the state, and local governments enforce it as written.
Local changesMassachusetts amendments are in 780 CMR; gas appliances and piping fall under 248 CMR.
Adopted byBoard of Building Regulations and Standards.In force since October 11, 2024.
Fuel gas248 CMR 4.00 to 8.00, Massachusetts Fuel Gas Code (NFPA 54 with the 248 CMR 5.00 amendments; NFPA 58 with 248 CMR 8.00)April 30, 2021
Applies toFuel gas piping systems, gas utilization equipment and related accessories throughout the Commonwealth.
Based on, and how far it reachesNFPA 54, 2012 edition.Applies across the state, and local governments enforce it as written.
Local changesMassachusetts amendments to NFPA 54 are in 248 CMR 5.00; large gas equipment in 248 CMR 7.00. The NFPA 54 edition (2012) comes from a summary of the 248 CMR 4.00 text and is not confirmed in the rule itself.
Adopted byBoard of State Examiners of Plumbers and Gas Fitters.In force since April 30, 2021.
Electrical527 CMR 12.00, Massachusetts Electrical CodeApril 24, 2026
Applies toAll electrical installations in the Commonwealth.
Based on, and how far it reachesNFPA 70, 2026 edition.Applies across the state, and local governments enforce it as written.
Local changesNFPA 70 (2026) with Massachusetts amendments, plus an emergency amendment for NEC 230.85 emergency disconnects and a GFCI unwanted-tripping documentation process.
Adopted byBoard of Fire Prevention Regulations (Department of Fire Services).In force since April 24, 2026.
Accessibility521 CMR, Architectural Access Board Rules and Regulations
Applies toAccessibility of public buildings and multiple dwellings in Massachusetts; the federal ADA applies separately.
Based on, and how far it reachesThe state's own code, 521 CMR (current rules).Applies across the state, and local governments enforce it as written.
Local changesA Massachusetts rule set, not ICC A117.1. Edition and scope thresholds were not confirmed.
Adopted byArchitectural Access Board.
Elevators and escalators524 CMR 35.00, Safety Code for Elevators and Escalators A17.1-2013 and the Massachusetts ModificationsJune 1, 2018
Applies toConstruction, installation, alteration and operation of all elevators, escalators, dumbwaiters, moving walks, lifts and hoists in Massachusetts.
Based on, and how far it reachesASME A17.1, 2013 edition.Applies across the state, and local governments enforce it as written.
Local changesMassachusetts modifications in 524 CMR 35.00, with separate chapters for platform lifts, parking devices, material hoists and construction hoists.
Adopted byBoard of Elevator Regulations (Office of Public Safety and Inspections).In force since June 1, 2018.
Pools and spas780 CMR, 10th Edition (2021 International Swimming Pool and Spa Code as amended)October 11, 2024
Applies toConstruction of pools, spas and hot tubs.
Based on, and how far it reachesISPSC, 2021 edition.Applies across the state, and local governments enforce it as written.
Local changesMassachusetts amendments are in 780 CMR.
Adopted byBoard of Building Regulations and Standards.In force since October 11, 2024.
Modular and factory-built buildingsManufactured buildings under 780 CMR
Applies toFactory-built (manufactured) buildings must meet 780 CMR, and their site construction must be overseen by a licensed construction supervisor or registered design professional like any other building. The details of the state approval program were not confirmed.
Based on, and how far it reachesThe state's own code (780 CMR 10th Edition).Applies across the state, and local governments enforce it as written.
Adopted byBoard of Building Regulations and Standards.
Structural loads780 CMR 10th Edition, Chapter 16 (Table 1604.11, design values by municipality)October 11, 2024
Applies toDesign loads. Section 1604.11 and Table 1604.11 give ground snow load, basic wind speed and seismic parameters for each city and town.
Based on, and how far it reachesASCE 7 with state table, 2016 edition.Applies across the state, and local governments enforce it as written.
Local changesThe chapter text was not confirmed; an engineering firm summary reports snow loads unchanged from the 9th Edition and wind speeds lower (Boston 120 mph and Worcester 117 mph for Risk Category II).
Adopted byBoard of Building Regulations and Standards.In force since October 11, 2024.
Not adopted here, or not found yet
Life safetyNFPA 101 status not confirmedNot found
Applies toNot confirmed whether NFPA 101 is adopted as a separate state code; egress for new buildings is in 780 CMR and the fire code is NFPA 1.
Based on, and how far it reachesNFPA 101.
Adopted byBoard of Fire Prevention Regulations.
Wildland-urban interfaceNo wildland-urban interface codeNo code of this kind is adopted
Applies toThe IWUIC is not adopted in Massachusetts.
Adopted byNot applicable.
Property maintenanceProperty maintenance standard not confirmedNot found
Applies toThe IPMC is not adopted statewide per the ICC chart. Minimum housing standards are in the State Sanitary Code (Department of Public Health), which was not confirmed.
Based on, and how far it reachesThe state's own code.
Adopted byDepartment of Public Health and local boards of health (not confirmed).
Sprinkler rules for housesSprinkler rules for one- and two-family dwellings not confirmedNot found
Applies toWhether 780 CMR Chapter 51 keeps, deletes or amends IRC R313 was not confirmed.
Based on, and how far it reachesIRC R313.
Adopted byBoard of Building Regulations and Standards.
Manufactured homesManufactured home installation rules not confirmedNot found
Applies toState installation standards for HUD-code manufactured homes were not confirmed.
Based on, and how far it reachesHUD code.
Not confirmed yet: who adopts it.
Flood rules beyond the federal minimumFlood provisions beyond the federal minimum not confirmedNot found
Applies to780 CMR carries the IBC and IRC flood provisions; any statewide freeboard was not confirmed. Local flood ordinances and the Wetlands Protection Act also apply.
Based on, and how far it reaches780 CMR.
Adopted byBoard of Building Regulations and Standards; municipalities.
Boilers and pressure vesselsBoiler and pressure vessel rules not confirmedNot found
Applies toMassachusetts boiler rules (Board of Boiler Rules) were not confirmed.
Based on, and how far it reachesThe state's own code.
Not confirmed yet: who adopts it.
Who designs, seals and builds
- Architect
- A registered architect is not required for any building with less than 35,000 cubic feet of enclosed space, for single- and two-family houses with their accessory buildings, for farm buildings, or for alterations that involve no substantial and major structural change. Registered engineers may do architectural work incidental to their engineering, and contractors may prepare shop drawings.MGL c.112 s.60A to 60O (exemptions in s.60L)Checked at the source
- Engineer
- Buildings over 35,000 cubic feet of enclosed space must be under the control of a registered design professional (architect or engineer) during construction, and that person takes the place of the construction supervisor. Smaller buildings, including one- and two-family homes, may be overseen by a licensed construction supervisor instead.780 CMR Chapter 1 (construction control); MGL c.112 s.81D to 81T (engineers)Checked at the source
- Contractor
- The Board of Building Regulations and Standards licenses construction supervisors (CSL), who must oversee work on one- and two-family homes and buildings under 35,000 cubic feet; contractors working on existing one- to four-family owner-occupied homes must also register as home improvement contractors. Plumbers and gas fitters are licensed by their state board and electricians by the Board of State Examiners of Electricians. Massachusetts does not recognize out-of-state contractor licenses.780 CMR Chapter 1; MGL c.142A (home improvement); MGL c.142 and c.112 s.61 to 65E (plumbers and gas fitters); MGL c.141 (electricians)Checked at the source
Design loads and hazards
- Wind
- Basic wind speed is listed for each municipality in 780 CMR Table 1604.11. An engineering firm summary of the 10th Edition gives about 120 mph for Boston and 117 mph for Worcester (Risk Category II), lower than the 9th Edition; Cape Cod and the islands are higher. Values not confirmed in the official table.
- Snow
- Ground snow load is listed for each municipality in 780 CMR Table 1604.11; reported as unchanged from the 9th Edition. Values not confirmed.
- Seismic
- Seismic parameters are listed for each municipality in 780 CMR Table 1604.11; values not confirmed.
- Frost depth
- Not confirmed (780 CMR Chapter 51 and local building officials set footing depth).
- Flood
- Not confirmed; FEMA flood maps and local floodplain bylaws apply, with coastal V and Coastal A zones along the shore.
Not confirmed for this place yet: other hazards.
Permits
- Who issues them
- Local building commissioners and inspectors in each of the 351 cities and towns issue building permits; local plumbing, gas and wiring inspectors issue trade permits; the Office of Public Safety and Inspections handles state-owned buildings. Not all of this is confirmed as of November 19, 2026.
- Review time limits
- Not confirmed.
- Private review
- Not confirmed. Larger buildings are controlled in construction by the registered design professional of record.
Cities and counties with their own codes
- Boston
Has adopted the Municipal Opt-in Specialized Energy Code (DOER list as of November 18, 2026).
- Cambridge
Has adopted the Municipal Opt-in Specialized Energy Code.
- Worcester
Has adopted the Municipal Opt-in Specialized Energy Code.
- Somerville
Has adopted the Municipal Opt-in Specialized Energy Code.
Where to read the codes, and who to ask
- Tenth edition of the MA State Building Code 780 (unofficial amendment text by chapter)
- Massachusetts Building Energy Codes (base, Stretch, Specialized)
- Energy code adoption by municipality (map and table)
- 527 CMR 1.00 Massachusetts Fire Code
- 527 CMR 12.00 Massachusetts Electrical Code
- 248 CMR plumbing and gas regulations
- 524 CMR elevator regulations
- MGL c.112 s.60L (architect exemptions)
- US DOE energy code status: Massachusetts
- Board of Building Regulations and Standards (Office of Public Safety and Inspections)Adopts 780 CMR; licenses construction supervisors; registers home improvement contractors
- Department of Energy Resources, Energy Efficiency DivisionWrites the Stretch and Specialized energy codes (225 CMR 22.00 and 23.00)
- Department of Fire Services, Board of Fire Prevention RegulationsAdopts the fire code (527 CMR 1.00) and electrical code (527 CMR 12.00)
- Board of State Examiners of Plumbers and Gas FittersPlumbing code (248 CMR 10.00), fuel gas code (248 CMR 4.00 to 8.00), licensing
- Board of Elevator RegulationsElevator code (524 CMR)
Not found yet
- The 780 CMR text of Chapter 16 (Table 1604.11) and the Chapter 51 amendments is not confirmed, so wind, snow, seismic and frost values, R313 sprinkler rules and flood freeboard are not given.
- Whether NFPA 101 is adopted in Massachusetts, and the State Sanitary Code (property maintenance), are not confirmed.
- NFPA 54 edition in 248 CMR 4.00 (reported as 2012) is not confirmed in the rule itself.
- 521 CMR accessibility rule edition, boiler rules, manufactured home installation rules and the manufactured buildings program are not confirmed.
- No 11th Edition schedule for 780 CMR was found.
- Permit time limits and any third-party review options were not confirmed.