The Oklahoma Uniform Building Code Commission (OUBCC), created in 2009, adopts the statewide minimum codes for all construction: building, residential, existing buildings, fire, plumbing, mechanical, fuel gas, electrical and energy. Local governments are not required to adopt and enforce codes, but those that do must use the OUBCC codes, and local amendments need OUBCC approval. Since September 14, 2026 the 2024 IBC, IRC, IEBC, IFC, IMC, IPC and IFGC are in force; the 2023 NEC has applied since September 14, 2024.

15 codes are in force here, 11 of them checked at the source, and this page was last updated November 19, 2026.

Codes in force

BuildingInternational Building Code, 2024 Edition, as adopted by the OUBCC (OAC 748:20-2)

Applies toCommercial construction statewide (everything outside the IRC). Applies wherever a local government enforces codes; local amendments must be approved by the OUBCC.

Based on, and how far it reachesIBC, 2024 edition.A minimum across the state that local governments may add to.

Local changesThe OUBCC chose not to adopt the 2021 IBC and went from the 2018 edition (in force September 14, 2021 to September 14, 2026) to the 2024 edition. Group E occupancies with an occupant load of 200 or more must have an ICC 500 storm shelter sized for enrolled students and staff, and storm shelters statewide are designed for 250 mph. The IECC reference is changed to the 2006 edition.

Adopted byOklahoma Uniform Building Code Commission.In force since September 14, 2026.

HousesInternational Residential Code, 2024 Edition, as adopted by the OUBCC (OAC 748:20-6)

Applies toOne- and two-family dwellings and townhouses statewide, wherever a local government enforces codes.

Based on, and how far it reachesIRC, 2024 edition.A minimum across the state that local governments may add to.

Local changesThe one- and two-family dwelling sprinkler requirement (R309.2) is moved to a new optional Appendix BP, so sprinklers are not required unless a jurisdiction adopts the appendix with OUBCC approval. Storm shelters follow ICC 500 and a storm shelter definition is added. Chapter 11 energy efficiency is adopted with modifications. Jurisdictions fill in Table R301.2 (wind, snow, frost depth, flood study). The 2018 IRC applied from September 14, 2022 to September 14, 2026.

Adopted byOklahoma Uniform Building Code Commission.In force since September 14, 2026.

Existing buildingsInternational Existing Building Code, 2024 Edition, as adopted by the OUBCC (OAC 748:20-8)

Applies toRepair, alteration, addition and change of occupancy of existing buildings statewide.

Based on, and how far it reachesIEBC, 2024 edition.A minimum across the state that local governments may add to.

Local changesThe OUBCC adoption page row for this rule shows a mistyped date and edition; the rule text itself states the 2024 IEBC is effective September 14, 2026.

Adopted byOklahoma Uniform Building Code Commission.In force since September 14, 2026.

FireInternational Fire Code, 2024 Edition, as adopted by the OUBCC

Applies toFire prevention and fire protection statewide; enforced by the State Fire Marshal and local fire officials.

Based on, and how far it reachesIFC, 2024 edition.A minimum across the state that local governments may add to.

Local changesThe 2018 IFC applied from September 14, 2021 to September 14, 2026.

Adopted byOklahoma Uniform Building Code Commission; Office of the State Fire Marshal.In force since September 14, 2026.

PlumbingInternational Plumbing Code, 2024 Edition, as adopted by the OUBCC

Applies toPlumbing in buildings outside the IRC, statewide.

Based on, and how far it reachesIPC, 2024 edition.A minimum across the state that local governments may add to.

Local changesThe 2018 IPC applied from September 14, 2021 to September 14, 2026.

Adopted byOklahoma Uniform Building Code Commission.In force since September 14, 2026.

MechanicalInternational Mechanical Code, 2024 Edition, as adopted by the OUBCC

Applies toMechanical systems in buildings outside the IRC, statewide.

Based on, and how far it reachesIMC, 2024 edition.A minimum across the state that local governments may add to.

Local changesThe 2018 IMC applied from September 14, 2021 to September 14, 2026.

Adopted byOklahoma Uniform Building Code Commission.In force since September 14, 2026.

Fuel gasInternational Fuel Gas Code, 2024 Edition, as adopted by the OUBCC

Applies toFuel gas piping and appliances statewide.

Based on, and how far it reachesIFGC, 2024 edition.A minimum across the state that local governments may add to.

Local changesThe 2018 IFGC applied from September 14, 2021 to September 14, 2026.

Adopted byOklahoma Uniform Building Code Commission.In force since September 14, 2026.

ElectricalNational Electrical Code, 2023 Edition, as adopted by the OUBCC

Applies toElectrical installations statewide.

Based on, and how far it reachesNFPA 70, 2023 edition.A minimum across the state that local governments may add to.

Local changesThe 2020 NEC applied from September 14, 2022 to September 14, 2024.

NextThe 2026 edition. The OUBCC technical review committee for the 2026 NEC has begun meeting (OUBCC page, September 2026).

Adopted byOklahoma Uniform Building Code Commission.In force since September 14, 2024.

Energy, housesIRC 2024 Chapter 11 (Energy Efficiency) with Oklahoma modifications

Applies toEnergy efficiency of new houses and townhouses statewide.

Based on, and how far it reachesIRC, 2024 edition.A minimum across the state that local governments may add to.

Local changesAir sealing details must follow Table N1102.5.1.1; the prescriptive path is limited to Sections N1101 through N1103; references to N1108 are removed; Table N1102.1.2 (U-factors and fenestration) is modified; ceilings without attics get a reduced insulation allowance. Before September 14, 2026, DOE recorded the 2018 IRC with state amendments (effective September 14, 2022), rated near the 2009 IECC.

Adopted byOklahoma Uniform Building Code Commission.In force since September 14, 2026.

Energy, other buildingsInternational Energy Conservation Code, 2006 Edition (referenced by the OUBCC building code)

Applies toEnergy efficiency of commercial buildings statewide.

Based on, and how far it reachesIECC, 2006 edition.A minimum across the state that local governments may add to.

Local changesThe OUBCC's 2024 IBC rule changes the IECC reference to the 2006 edition. DOE lists the 2006 IECC with state amendments effective September 14, 2022.

NextThe 2021 edition or 2024 IECC. The OUBCC energy code technical committee is reviewing the commercial provisions of the 2021 and 2024 IECC.

Adopted byOklahoma Uniform Building Code Commission.In force since September 14, 2022.

AccessibilityIBC 2024 Chapter 11 and the ICC A117.1 edition it references

Applies toAccessibility of buildings under the IBC. Oklahoma changes to Chapter 11 are not confirmed; the federal ADA applies separately.

Based on, and how far it reachesICC A117.1, 2017 edition.A minimum across the state that local governments may add to.

Adopted byOklahoma Uniform Building Code Commission.In force since September 14, 2026.

Wildland-urban interfaceInternational Wildland-Urban Interface Code (local adoption)

Applies toICC lists the IWUIC as adopted by one or more Oklahoma jurisdictions; it is not an OUBCC statewide code.

Based on, and how far it reachesIWUIC; the edition varies.Each city or county chooses whether to adopt it, and which edition.

Adopted byLocal governments.

Property maintenanceInternational Property Maintenance Code (local adoption)

Applies toICC lists local adoptions; ICC notes some I-codes are adopted by local governments outside the OUBCC set.

Based on, and how far it reachesIPMC; the edition varies.Each city or county chooses whether to adopt it, and which edition.

Adopted byLocal governments.

Not yet checked at the source
Sprinkler rules for housesIRC R309.2 house sprinkler requirement moved to optional Appendix BP

Applies toAutomatic sprinklers are not required in one- and two-family dwellings; the requirement sits in optional Appendix BP. Townhouse sprinklers (R309.1) are modified to allow a rated wall alternative.

Based on, and how far it reachesIRC, 2024 edition.A minimum across the state that local governments may add to.

Adopted byOklahoma Uniform Building Code Commission.In force since September 14, 2026.

Structural loadsStructural loads through the 2024 IBC (ASCE 7-22) and IRC, with Oklahoma storm shelter rules

Applies toDesign loads for buildings; storm shelters built under ICC 500 are designed for 250 mph statewide.

Based on, and how far it reachesASCE 7, 2022 edition.A minimum across the state that local governments may add to.

Adopted byOklahoma Uniform Building Code Commission.In force since September 14, 2026.

Not adopted here, or not found yet

Pools and spasInternational Swimming Pool and Spa Code (review complete, rulemaking pending)No code of this kind is adopted

Applies toNot yet adopted statewide. The OUBCC reports its ISPSC review is complete and the commission approved it with amendments; rulemaking will start once draft rules are approved.

Based on, and how far it reachesISPSC.

NextISPSC (edition not stated). Rulemaking to begin after draft rules are approved (OUBCC page dated September 16, 2026).

Adopted byOklahoma Uniform Building Code Commission.

Green building and stretch codesNo statewide green or stretch codeNo code of this kind is adopted

Applies toICC lists no IgCC adoption in Oklahoma.

Adopted byNone.

Manufactured homesManufactured home installationNot found

Based on, and how far it reachesHUD code.

Not confirmed yet: what it applies to and who adopts it.

Not yet checked at the source
Modular and factory-built buildingsModular and factory-built buildingsNot found

Based on, and how far it reachesThe state's own code.

Not confirmed yet: what it applies to and who adopts it.

Not yet checked at the source
Flood rules beyond the federal minimumFloodplain managementNot found

Applies toCommunities participating in the National Flood Insurance Program adopt floodplain ordinances; the IRC rule asks jurisdictions to name their flood study and floodplain ordinance. A statewide freeboard above the federal minimum was not confirmed.

Based on, and how far it reachesNFIP.

Not confirmed yet: who adopts it.

Not yet checked at the source
Elevators and escalatorsElevators and escalatorsNot found

Based on, and how far it reachesASME A17.1.

Not confirmed yet: what it applies to and who adopts it.

Not yet checked at the source
Boilers and pressure vesselsBoilers and pressure vesselsNot found

Based on, and how far it reachesASME.

Not confirmed yet: what it applies to and who adopts it.

Not yet checked at the source

Who designs, seals and builds

Architect
An architect is required for buildings of any size in Group I (institutional), dormitory-type R-2, A-1, A-4, A-5 and H, and for changes of occupancy. Exempt (basements not counted as stories): buildings of no more than two stories for A-2, A-3 and E with an occupant load of 50 or less; R-1 hotels and motels with up to 64 units; B buildings up to 100,000 sq ft; M buildings up to 200,000 sq ft; U, F and S buildings; apartments with up to 32 units per building; R-3 and R-4; public buildings under $300,000; and uninhabitable private agricultural buildings. Single-family residences built under the IRC are outside the act. Changes that do not affect structure, systems, life safety or egress are exempt.59 O.S. 46.21b, as amended by SB 751 (2025), which became law without the Governor's signature on May 14, 2025, effective November 1, 2025Checked at the source
Engineer
Engineers are licensed by the State Board of Licensure for Professional Engineers and Land Surveyors. A joint task force with the Board of Architects clarified which services belong to engineering, to architecture, or to both (reflected in the 2024 statute changes). Seal thresholds for buildings are not confirmed.59 O.S. 475.1 et seq. (Engineering and Land Surveying Act; not confirmed)Not yet checked at the source
Contractor
Oklahoma does not license general contractors at the state level; local jurisdictions may. The Construction Industries Board licenses electrical, mechanical and plumbing contractors and journeymen, building inspectors and home inspectors, and registers roofing contractors.Checked at the source

Design loads and hazards

Wind
Basic wind speeds from the ASCE 7 maps referenced by the IBC and IRC; jurisdictions fill in the IRC Table R301.2 values. Storm shelters are designed for 250 mph statewide.
Snow
Ground snow loads from the IRC and ASCE 7 maps (Figure R301.2(3)), filled in by each jurisdiction; no state snow study was found.
Seismic
From the IRC and ASCE 7 maps; values not taken from an Oklahoma table.
Frost depth
Each jurisdiction fills in its frost line depth in IRC Table R301.2.
Flood
Jurisdictions name their floodplain ordinance and flood insurance study in IRC Table R301.2; NFIP rules apply.
Other hazards
Tornado risk is high: schools (Group E with 200 or more occupants) need ICC 500 storm shelters. Expansive clay soils are common.

Permits

Who issues them
Cities and counties that choose to enforce codes issue permits, using the OUBCC codes. Local amendments need OUBCC approval. Jurisdictions report permits to the OUBCC through its online reporting portal. The Construction Industries Board licenses the inspectors.
Review time limits
No statewide plan review deadline was found.
Private review
No state program for private plan review or inspection was found.

Cities and counties with their own codes

  • Oklahoma City

    Enforces the OUBCC codes; any local amendments must be approved by the OUBCC. The city's current amendments are not confirmed.

  • Tulsa

    Enforces the OUBCC codes; any local amendments must be approved by the OUBCC. The city's current amendments are not confirmed.

Where to read the codes, and who to ask

Not found yet

  • Accessibility, structural (ASCE 7 edition) and design values follow from the adopted 2024 IBC and IRC but Oklahoma changes to those chapters are not confirmed.
  • Elevator, boiler, manufactured home installation, modular, floodplain and public pool rules are not confirmed.
  • Engineer seal requirements and the engineering statute were not confirmed.
  • Whether the State Fire Marshal adopts NFPA 101 for any occupancies is not confirmed.
  • The OUBCC permit fee and reporting rules were not confirmed.
  • Oklahoma City and Tulsa amendments are not confirmed.