Skip to content

Oregon

Oregon has one uniform state building code (ORS chapter 455). The Building Codes Division of the Department of Consumer and Business Services adopts each specialty code (structural, residential, mechanical, plumbing, electrical, energy, elevator, boiler, manufactured dwelling), and no city or county may enact different requirements unless the Division authorizes it (ORS 455.040). Municipalities that take on a building inspection program enforce the code and issue permits; the Division does so elsewhere. The State Fire Marshal adopts the Oregon Fire Code. New codes usually take effect with a six-month phase-in during which either edition may be used.

20 codes are in force here, 17 of them checked at the source, and this page was last updated November 19, 2026.

Codes in force

Building2025 Oregon Structural Specialty Code (OSSC)

Applies toAll buildings other than those under the Oregon Residential Specialty Code: commercial, multifamily, institutional and high-rise buildings. Based on the 2024 IBC, with parts of the 2024 IFC and IEBC.

Based on, and how far it reachesIBC, 2024 edition.Applies across the state, and local governments enforce it as written.

Local changesChapter 1 was effective and mandatory October 1, 2025; the rest had a six-month phase-in, mandatory April 1, 2026, during which the 2022 OSSC could be used. Interim amendments to Chapter 34 address snow load provisions for repairs and alterations. Oregon amendments apply statewide; ORS 455.447 adds seismic and tsunami rules for essential facilities and major structures.

NextA newer OSSC, based on the 2027 IBC. Not yet announced; the OSSC has followed a three-year cycle (2019, 2022, 2025).

Adopted byBuilding Codes Division (Department of Consumer and Business Services); municipal building departments and the Division enforce.In force since October 1, 2025.

Houses2026 Oregon Residential Specialty Code (ORSC)

Applies toConstruction of residential dwellings three stories or less above grade: one- and two-family dwellings, townhouses and their accessory structures (ORS 455.610, the Low-Rise Residential Dwelling Code). Based on the 2024 IRC.

Based on, and how far it reachesIRC, 2024 edition.Applies across the state, and local governments enforce it as written.

Local changesChapter 1 was effective and mandatory October 1, 2026; Chapters 2 to 44 and the appendices have a six-month phase-in to April 1, 2027, during which the 2023 ORSC (2021 IRC) may still be used. Local governments may not adopt a list of preempted appendices, including tiny houses, ADUs, home day care, solar-ready, zero net energy, EV charging infrastructure, the 2024 IECC stretch code and electric-ready provisions. Section R327 (wildfire hazard mitigation) applies only where a municipality adopts it. Small home construction standards (HB 2423, 2019) moved into the ORSC on January 1, 2026.

Adopted byBuilding Codes Division; municipal building departments enforce.In force since October 1, 2026.

Existing buildingsExisting building provisions of the 2025 OSSC (based on the 2024 IEBC)

Applies toRepairs, alterations, additions and changes of occupancy of existing buildings under the OSSC, which incorporates IEBC provisions; houses under the ORSC follow its own rules for existing buildings.

Based on, and how far it reachesIEBC, 2024 edition.Applies across the state, and local governments enforce it as written.

Local changesInterim amendments to OSSC Chapter 34 on snow load provisions for repairs and alterations.

Adopted byBuilding Codes Division.In force since October 1, 2025.

Energy, housesResidential energy provisions of the 2026 ORSC (Chapter 11)

Applies toEnergy efficiency of new homes and additions under the ORSC. Chapter 11 of the 2026 ORSC becomes mandatory April 1, 2027; until then the 2023 ORSC energy provisions may be used, which DOE rates as equivalent to the 2018 IECC.

Based on, and how far it reachesThe state's own code, 2026.Applies across the state, and local governments enforce it as written.

Local changesOregon amends the residential energy provisions in ORSC Chapter 11 (DOE lists state amendments). Section R109.1.7 applies with Chapter 11 and is not mandatory until April 1, 2027. The Oregon Residential Reach Code is an optional higher standard (see the green entry); locals may not adopt the 2024 IECC stretch appendix.

Adopted byBuilding Codes Division.In force since October 1, 2026.

Energy, other buildings2025 Oregon Energy Efficiency Specialty Code (OEESC)

Applies toEnergy efficiency of commercial buildings and other buildings under the OSSC. Based on ASHRAE 90.1-2022 with Oregon amendments.

Based on, and how far it reachesASHRAE 90.1, 2022 edition.Applies across the state, and local governments enforce it as written.

Local changesSix-month phase-in; mandatory July 1, 2025. DOE lists Oregon amendments that lower efficiency about 4.8 percent against the model.

Adopted byBuilding Codes Division.In force since January 1, 2025.

Fire2025 Oregon Fire Code (OFC)

Applies toFire prevention, fire protection systems, hazardous materials and fire department access for buildings and premises statewide. Based on the 2024 IFC with Oregon amendments.

Based on, and how far it reachesIFC, 2024 edition.A minimum across the state that local governments may add to.

Local changesA 180-day period from October 1, 2025 to March 31, 2026 let building officials use the 2022 or 2025 OFC for new construction plan reviews; the 2022 OFC is no longer valid for that. Changes summarized by the State Fire Marshal include Section 320 (lithium-ion and lithium metal battery storage) and Section 322 (powered micromobility devices). Local fire jurisdictions can submit code proposals to the State Fire Marshal.

Adopted byOregon State Fire Marshal; local fire agencies enforce.In force since October 1, 2025.

Plumbing2026 Oregon Plumbing Specialty Code (OPSC)

Applies toPlumbing in all buildings. Based on the 2024 UPC with Oregon amendments.

Based on, and how far it reachesUPC, 2024 edition.Applies across the state, and local governments enforce it as written.

Local changesOregon amendments in the final code adoption matrix.

Adopted byBuilding Codes Division; municipal building departments enforce.In force since October 1, 2026.

Mechanical2025 Oregon Mechanical Specialty Code (OMSC)

Applies toMechanical systems in buildings under the OSSC. Based on the 2024 IMC and IFGC.

Based on, and how far it reachesIMC, 2024 edition.Applies across the state, and local governments enforce it as written.

Local changesSix-month phase-in; mandatory April 1, 2026, with the 2022 OMSC usable until then.

Adopted byBuilding Codes Division.In force since October 1, 2025.

Fuel gasFuel gas provisions of the 2025 Oregon Mechanical Specialty Code (2024 IFGC)

Applies toFuel gas piping and appliances in buildings under the OSSC; houses follow the ORSC fuel gas chapters.

Based on, and how far it reachesIFGC, 2024 edition.Applies across the state, and local governments enforce it as written.

Local changesMandatory April 1, 2026.

Adopted byBuilding Codes Division.In force since October 1, 2025.

Electrical2026 Oregon Electrical Specialty Code (OESC)

Applies toElectrical installations statewide. Based on the 2026 NEC; Oregon issues a table of amendments to be used with the NEC rather than an integrated codebook.

Based on, and how far it reachesNFPA 70, 2026 edition.Applies across the state, and local governments enforce it as written.

Local changesTable of Oregon amendments to the 2026 NEC (Table 1-E). The previous 2023 OESC took effect October 1, 2023.

Adopted byBuilding Codes Division; municipal electrical programs enforce.In force since October 1, 2026.

AccessibilityAccessibility under OSSC Chapter 11 (2024 IBC with Oregon amendments)

Applies toAccessibility in buildings under the OSSC; the federal ADA applies separately.

Based on, and how far it reachesIBC, 2024 edition.Applies across the state, and local governments enforce it as written.

Local changesOregon amendments not confirmed.

Adopted byBuilding Codes Division.In force since October 1, 2025.

Not yet checked at the source
Elevators and escalators2024 Oregon Elevator Specialty Code

Applies toInstallation, alteration, repair and maintenance of elevators operated in the state: ASME A17.1-2019 with Oregon amendments (OAR 918-400-0455), plus ASME A17.2-2020 (inspection guide), A17.3-2020 (existing elevators), A17.6-2022, A17.7-2007 and A18.1-2020 (platform lifts and stairway chairlifts).

Based on, and how far it reachesASME A17.1, 2019 edition.Applies across the state, and local governments enforce it as written.

Local changesTable 2-L lists the Oregon amendments to ASME A17.1-2019. ASME A17.3-2020 had a phase-in from January 1 to July 1, 2024.

Adopted byBuilding Codes Division, Elevator Program.

Checked at the source
Boilers and pressure vessels2024 Oregon Boiler and Pressure Vessel Specialty Code (OBPVSC)

Applies toInstallation, alteration and repair of boilers, pressure vessels, pressure piping and related items: 2023 ASME Boiler and Pressure Vessel Code, 2023 National Board Inspection Code, ASME B31.1-2024, B31.3-2022, B31.5-2022, B31.9-2023, NFPA 85 (2023), ASME CSD-1 (2021) and ASME PVHO-1 (2023).

Based on, and how far it reachesASME BPVC, 2023 edition.Applies across the state, and local governments enforce it as written.

Local changesOregon amendments in Table 2-b.

Adopted byBuilding Codes Division, Boiler and Pressure Vessel Program.

Green building and stretch codesOregon Reach Code (residential and commercial)

Applies toA statewide optional energy construction standard, separate from the state building code, that designers and contractors may choose to follow for buildings under the ORSC (2023 Oregon Residential Reach Code) or the OSSC (Commercial Reach Code). It does not limit the building official's authority over alternate methods.

Based on, and how far it reachesThe state's own code, 2023.Applies across the state to some buildings only, such as public buildings, schools and hospitals.

Local changesTied to Executive Orders 17-20 and 20-04 on energy and emissions.

Adopted byBuilding Codes Division.

Checked at the source
Wildland-urban interfaceORSC Section R327, Wildfire Hazard Mitigation (local option)

Applies toWhere a municipality's building department adopts R327, new one- and two-family dwellings and certain new accessory structures in locally designated wildfire hazard zones must meet ignition-resistant construction standards (roofs, siding, windows, vents and other openings). Elsewhere the standards may be followed voluntarily. The Design Criteria Hub shows whether a location's municipality has adopted R327.

Based on, and how far it reachesThe state's own code, 2026.Each city or county chooses whether to adopt it, and which edition.

Local changesBCD published R327 amendments for the 2023 ORSC and keeps a list of municipalities that have adopted R327.

Adopted byMunicipal building departments adopt; Building Codes Division.

Property maintenanceProperty maintenance (local)

Applies toNo statewide property maintenance code. The ORSC lists abatement of nuisances and dangerous buildings among matters left to local governments; cities such as Portland keep their own property maintenance codes (not confirmed).

Based on, and how far it reachesIPMC; the edition varies by city.Each city or county chooses whether to adopt it, and which edition.

Adopted byCities and counties.

Manufactured homes2010 Oregon Manufactured Dwelling Installation Specialty Code (OMDISC) and 2002 Oregon Manufactured Dwelling and Parks Specialty Code

Applies toInstallation of manufactured dwellings (HUD-code homes, ORS 446.003) and manufactured dwelling parks. The Division also runs the manufactured dwelling construction program on behalf of HUD.

Based on, and how far it reachesThe state's own code, 2010.Applies across the state, and local governments enforce it as written.

Local changesStatewide code interpretation 11-01 covers flood hazard areas; the parks code includes amendments effective April 1, 2005.

Adopted byBuilding Codes Division; Residential and Manufactured Structures Board.In force since April 1, 2010.

Modular and factory-built buildingsPrefabricated structures program (ORS 455.705)

Applies toPrefabricated structures and components need plan approval and inspection by the Division or by persons it certifies or approves, and an insignia of compliance or certification stamp for certain transactions; manufacturers may run a compliance program.

Based on, and how far it reachesThe state's own code, current edition.Applies across the state, and local governments enforce it as written.

Adopted byBuilding Codes Division.

Flood rules beyond the federal minimumFlood rules: local NFIP administration and state tsunami inundation zone

Applies toThe ORSC leaves administration and implementation of the National Flood Insurance Program to local governments. DOGAMI's board sets the tsunami inundation zone by rule (ORS 455.446), and ORS 455.447 adds rules for structures vulnerable to earthquakes and tsunamis.

Based on, and how far it reachesThe state's own code, current edition.Each city or county chooses whether to adopt it, and which edition.

Adopted byCities and counties (NFIP); Department of Geology and Mineral Industries (tsunami zone).

Structural loadsASCE 7 through the 2025 OSSC, with Oregon design criteria and ORS 455.447

Applies toDesign loads under the OSSC (the 2024 IBC references ASCE 7-22). Site-specific ground snow load, basic wind speed, seismic ground motion values and frost depth come from the Oregon Design Criteria Hub. ORS 455.447 applies ASCE 7-based seismic and tsunami rules to major structures (for example buildings over six stories with 60,000 square feet or more) and essential facilities.

Based on, and how far it reachesASCE 7, 2022 edition.Applies across the state, and local governments enforce it as written.

Local changesInterim amendments on snow load provisions for repairs and alterations (OSSC Chapter 34).

Adopted byBuilding Codes Division.In force since October 1, 2025.

Not yet checked at the source

Not adopted here, or not found yet

Life safetyNFPA 101, Life Safety Code (not a specialty code)No code of this kind is adopted

Applies toNFPA 101 is not one of Oregon's specialty codes; life safety rules come from the OSSC and the Oregon Fire Code. Health care facilities in federal programs follow the CMS-required edition (see the federal page).

Based on, and how far it reachesNFPA 101.

Adopted byNot adopted.

Pools and spasSwimming poolsNot found

Applies toNo pool specialty code is listed among the Division's code programs; public pools are regulated by the Oregon Health Authority (not confirmed) and residential pools through the structural and residential codes.

Adopted byNot found.

Not yet checked at the source
Sprinkler rules for housesResidential sprinklers under the ORSCNot found

Applies toHow the 2026 ORSC treats IRC sprinkler requirements for one- and two-family dwellings and townhouses is not confirmed.

Based on, and how far it reachesIRC, 2024 edition.

Adopted byBuilding Codes Division.

Not yet checked at the source

Who designs, seals and builds

Architect
A person who is not an architect may prepare plans for, and provide construction phase services on, a single family residential dwelling or farm building, structures auxiliary to them (such as a three-car garage, barn or shed), and any building with a ground area of 4,000 square feet or less that is not more than 20 feet from the lowest floor surface to the highest interior overhead finish. Alterations and repairs that do not involve structural parts or change the occupancy or construction type are also exempt. Other buildings need a registered architect.ORS 671.030Checked at the source
Engineer
Structural engineering services on significant structures need structural engineer registration: hazardous facilities and special occupancy structures (Risk Category III), essential facilities (Risk Category IV) with more than 4,000 square feet of ground area or more than 20 feet in height, structures the Division finds irregular, and occupied buildings over four stories or 45 feet. One- and two-family dwellings and their accessory structures, agricultural buildings and equine facilities are not significant structures.ORS 672.107Checked at the source
Contractor
Anyone who bids on or does work as a contractor must hold a current license from the Construction Contractors Board with the right endorsement; residential work needs a residential endorsement (for example residential general contractor).ORS 701.021Checked at the source

Design loads and hazards

Wind
Basic design wind speed for any site comes from the Oregon Design Criteria Hub (ORSC and OSSC).
Snow
Ground snow load for any site comes from the Oregon Design Criteria Hub; the OSSC has interim amendments on snow load provisions for repairs and alterations.
Seismic
Seismic Design Category (ORSC) and seismic ground motion values (OSSC) come from the Design Criteria Hub. ORS 455.447 adds site-specific requirements for major structures and essential facilities vulnerable to earthquakes and tsunamis.
Frost depth
Frost line depth and air freezing index come from the Design Criteria Hub.
Flood
NFIP administration is a local matter under the ORSC; DOGAMI sets the tsunami inundation zone (ORS 455.446).
Other hazards
The Hub also shows weathering and decay potential, whether new dwelling construction needs radon mitigation, and whether the municipality has adopted R327 wildfire hazard mitigation.

Permits

Who issues them
Cities and counties that assume a building inspection program (ORS 455.148 comprehensive programs, or 455.150 selective programs assumed before 2002) issue permits for the state building code, manufactured dwelling installation, parks and related programs; the Building Codes Division administers the code where no municipality has assumed it.
Review time limits
For specialty code plan reviews of simple low-rise residential dwellings, the Division or municipality must approve or disapprove a complete application within 10 business days (jurisdictions under 300,000 people) or 15 business days (300,000 or more), unless it uses the ORS 455.465 alternative; complex structures and plans needing other agencies' approval are excepted. Municipalities must offer phased permits and deferred submittals for commercial projects.
Private review
The Division licenses specialty code inspectors and plan reviewers (ORS 455.457). As the alternative to the residential deadlines, a jurisdiction must designate at least three licensed persons whose plan reviews it will accept, or contract with a licensed plan reviewer (ORS 455.465).

Cities and counties with their own codes

Where to read the codes, and who to ask

Not found yet

  • Whether the 2026 OPSC and 2026 OESC have phase-in periods is not confirmed; both are effective October 1, 2026.
  • Effective dates of the 2024 Oregon Elevator and Boiler and Pressure Vessel Specialty Codes were not found.
  • How the 2026 ORSC handles IRC residential sprinkler requirements is not confirmed.
  • Whether the statewide wildfire hazard map and related home hardening mandate (SB 762, SB 80) were repealed in 2025 was not confirmed; BCD presents R327 as a local option.
  • Accessibility amendments, Oregon Health Authority pool rules and electrical and plumbing trade licensing are not confirmed.
  • The model base of the 2023 OPSC and the timing of the next OSSC were not confirmed.
  • Local programs in Portland, Eugene and Salem are not confirmed.