Philadelphia
Philadelphia enforces the Pennsylvania Uniform Construction Code with local modifications through Title 4 of the Philadelphia Code, the Building Construction and Occupancy Code, administered by the Department of Licenses and Inspections (L&I). The city's Administrative Code stays in force as a local construction code within the UCC, and the city licenses contractors and trades. Since January 1, 2026 the city follows the 2021 ICC codes as adopted by the Commonwealth and local ordinance; every application received from July 1, 2026 must use them.
16 codes are in force here, 15 of them checked at the source, and this page was last updated November 19, 2026.
Codes in force
Building2021 Philadelphia Building Construction and Occupancy Code, Building Code (Title 4, 2021 IBC as amended by the Commonwealth and local ordinance)January 1, 2026
Applies toAll buildings other than those under the IRC. Applications received before July 1, 2026 could choose the 2018 or 2021 codes (2018 by default); all applications received on or after July 1, 2026, including trade permits, must meet the 2021 codes. Master permit approvals under the 2018 codes are valid only for building permits filed before July 1, 2026.
Based on, and how far it reachesIBC, 2021 edition.A state minimum that the city may add to.
Local changesLocal modifications in Title 4; the Philadelphia Administrative Code remains a component of the UCC in the city.
NextThe 2024 edition. Follows the Commonwealth's 2024 code review (RAC comments open until February 2, 2027).
Adopted byDepartment of Licenses and Inspections; City Council for local amendments.In force since January 1, 2026.
Houses2021 Philadelphia Building Construction and Occupancy Code, Residential Code (2021 IRC as adopted)January 1, 2026
Applies toOne- and two-family dwellings and townhouses within the IRC scope.
Based on, and how far it reachesIRC, 2021 edition.A state minimum that the city may add to.
Local changesSame transition rules as the building code (choice of 2018 or 2021 before July 1, 2026).
NextThe 2024 edition. Follows the Commonwealth's 2024 code review.
Adopted byDepartment of Licenses and Inspections.In force since January 1, 2026.
Existing buildings2021 Philadelphia Building Construction and Occupancy Code, Existing Building Code (2021 IEBC as adopted)January 1, 2026
Applies toRepairs, alterations, additions and changes of occupancy of existing buildings.
Based on, and how far it reachesIEBC, 2021 edition.A state minimum that the city may add to.
Local changesAccessibility provisions remain those of the 2018 IEBC.
NextThe 2024 edition. Follows the Commonwealth's 2024 code review.
Adopted byDepartment of Licenses and Inspections.In force since January 1, 2026.
Energy, houses2021 International Energy Conservation Code as adopted in the UCC and Title 4 (residential)January 1, 2026
Applies toEnergy efficiency of new houses and low-rise residential buildings.
Based on, and how far it reachesIECC, 2021 edition.A state minimum that the city may add to.
Local changesCommonwealth amendments apply (see PA).
NextThe 2024 edition. Follows the Commonwealth's 2024 code review.
Adopted byDepartment of Licenses and Inspections.In force since January 1, 2026.
Energy, other buildings2021 International Energy Conservation Code as adopted in the UCC and Title 4 (commercial)January 1, 2026
Applies toEnergy efficiency of commercial buildings; the 2021 IECC allows ASHRAE 90.1-2019 as an alternative.
Based on, and how far it reachesIECC, 2021 edition.A state minimum that the city may add to.
Local changesCommonwealth amendments apply (see PA).
NextThe 2024 edition. Follows the Commonwealth's 2024 code review.
Adopted byDepartment of Licenses and Inspections.In force since January 1, 2026.
FirePhiladelphia Fire Code (2018 International Fire Code, with the 2021 IFC where the 2021 building codes reference it)
Applies toFire safety in existing buildings and premises in the city; new construction uses the 2021 IFC provisions referenced by the 2021 IBC and IEBC.
Based on, and how far it reachesIFC, 2018 edition.The city adopts it itself.
Adopted byDepartment of Licenses and Inspections and the Philadelphia Fire Department.
Plumbing2021 International Plumbing Code as adopted in the UCC and Title 4January 1, 2026
Applies toPlumbing systems, installed by registered master plumbers. Most plumbing plans do not need a design professional's seal.
Based on, and how far it reachesIPC, 2021 edition.A state minimum that the city may add to.
Local changesAccessibility provisions remain those of the 2018 IPC.
NextThe 2024 edition. Follows the Commonwealth's 2024 code review.
Adopted byDepartment of Licenses and Inspections.In force since January 1, 2026.
Mechanical2021 International Mechanical Code as adopted in the UCC and Title 4January 1, 2026
Applies toMechanical systems; ductwork and work on appliances connected to a chimney or flue need a specialized trade license.
Based on, and how far it reachesIMC, 2021 edition.A state minimum that the city may add to.
NextThe 2024 edition. Follows the Commonwealth's 2024 code review.
Adopted byDepartment of Licenses and Inspections.In force since January 1, 2026.
Fuel gas2021 International Fuel Gas Code as adopted in the UCC and Title 4January 1, 2026
Applies toFuel gas piping and appliances.
Based on, and how far it reachesIFGC, 2021 edition.A state minimum that the city may add to.
NextThe 2024 edition. Follows the Commonwealth's 2024 code review.
Adopted byDepartment of Licenses and Inspections.In force since January 1, 2026.
Electrical2020 National Electrical Code (referenced standard of the 2021 codes)January 1, 2026
Applies toElectrical work, performed by licensed electrical contractors. Electrical plans must be sealed by a professional engineer for installations of 100 kW or 400 amps or more, including service upgrades of that size.
Based on, and how far it reachesNFPA 70, 2020 edition.A state minimum that the city may add to.
Adopted byDepartment of Licenses and Inspections.In force since January 1, 2026.
AccessibilityAccessibility provisions of the 2018 International Codes (2021 updates enjoined)
Applies toAccessible design. Because a 2022 Commonwealth Court ruling enjoined the 2021 accessibility provisions, the accessibility provisions of the 2018 IBC, IEBC, IPC and ISPSC, with ICC A117.1-2009, stay in effect until the Commonwealth adopts new ones. The federal ADA applies separately.
Based on, and how far it reachesIBC Chapter 11 and ICC A117.1 (2018 IBC; ICC A117.1-2009).A state code that applies in the city as written.
Adopted byCommonwealth (Department of Labor and Industry); enforced by L&I.
Elevators and escalatorsElevators (Commonwealth jurisdiction under the UCC)
Applies toThe Pennsylvania Department of Labor and Industry has sole jurisdiction over all elevators; the edition in force was not confirmed.
Based on, and how far it reachesASME A17.1; the edition is not confirmed.A state code that applies in the city as written.
Adopted byPennsylvania Department of Labor and Industry.
Pools and spasSwimming pools under the UCC (2021 ISPSC as adopted by the Commonwealth)January 1, 2026
Applies toPools and spas; accessibility provisions remain those of the 2018 ISPSC. Local Philadelphia rules for pools are not confirmed.
Based on, and how far it reachesISPSC, 2021 edition.A state minimum that the city may add to.
Adopted byDepartment of Licenses and Inspections.In force since January 1, 2026.
Wildland-urban interfaceIWUIC (part of the statewide UCC)January 1, 2026
Applies toPart of the UCC statewide; no wildland-urban interface areas are expected in the city. Not confirmed locally.
Based on, and how far it reachesIWUIC, 2021 edition.A state minimum that the city may add to.
Adopted byPennsylvania Department of Labor and Industry.In force since January 1, 2026.
Other2021 ICC Performance Code for Buildings and FacilitiesJanuary 1, 2026
Applies toAn alternative performance-based path for design, adopted with the 2021 codes.
Based on, and how far it reachesICCPC, 2021 edition.A state minimum that the city may add to.
Adopted byDepartment of Licenses and Inspections.In force since January 1, 2026.
OtherPhiladelphia Zoning Code (Title 14 of the Philadelphia Code)
Applies toZoning approval is part of the permit process; zoning plans usually do not need an architect's or engineer's seal.
Based on, and how far it reachesThe city's own law (Title 14).The city adopts it itself.
Adopted byDepartment of Licenses and Inspections; Zoning Board of Adjustment.
Not adopted here, or not found yet
Life safetyNFPA 101 not adoptedNo code of this kind is adopted
Applies toThe city's applicable codes are the ICC codes, the NEC and NFPA 72; NFPA 101 is not among them. Not confirmed beyond L&I's code list.
Based on, and how far it reachesNFPA 101.
Adopted byNot applicable.
Green building and stretch codesNo local green building code foundNot found
Applies toCity green building or benchmarking rules were not confirmed.
Not confirmed yet: who adopts it.
Property maintenancePhiladelphia Property Maintenance Code (Title 4) not confirmedNot found
Applies toPhiladelphia keeps a property maintenance code in Title 4; its model edition was not confirmed.
Based on, and how far it reachesIPMC.
Adopted byDepartment of Licenses and Inspections.
Sprinkler rules for housesSprinkler rules for houses not confirmedNot found
Applies toNot confirmed (Commonwealth rule applies; see PA).
Based on, and how far it reachesIRC R313.
Adopted byDepartment of Licenses and Inspections.
Flood rules beyond the federal minimumFloodplain rules not confirmedNot found
Applies toPhiladelphia floodplain requirements were not confirmed.
Based on, and how far it reachesThe city's own law.
Not confirmed yet: who adopts it.
Who designs, seals and builds
- Architect
- Building plans must be sealed by a registered design professional, except for a non-structural alteration (no change to bearing walls or floor framing) costing less than $25,000. Where no professional is required, the owner or an agent may prepare scaled, professional-quality plans. Licenses are verified with the Pennsylvania Department of State.Philadelphia Code Title 4 (Administrative Code); Pennsylvania Architects Licensure LawChecked at the source
- Engineer
- Electrical plans must be sealed by a professional engineer for installations or service upgrades of 100 kW or 400 amps or more; some alterations need a report from a Pennsylvania-licensed engineer. Most plumbing plans need no seal.Philadelphia Code Title 4Checked at the source
- Contractor
- A licensed contractor must perform all work. Most general construction needs a Philadelphia Contractor License; general work on an existing one- or two-family dwelling may be done with the Pennsylvania Home Improvement Registration plus a Commercial Activity License and equivalent insurance. Electrical work needs a licensed electrical contractor, plumbing a registered master plumber, sprinkler work a fire suppression contractor; demolition, duct work and work on appliances connected to a chimney or flue also need specialized trade licenses.Philadelphia Code Title 9 and Title 4Checked at the source
Design loads and hazards
- Wind
- Not confirmed; the 2021 IBC and IRC maps apply (ASCE 7-16).
- Flood
- Not confirmed; parts of the city along the Delaware and Schuylkill rivers are in FEMA flood zones.
Not confirmed for this place yet: snow, seismic, frost depth.
Permits
- Who issues them
- The Department of Licenses and Inspections issues building, zoning, electrical, plumbing and other permits, online through eCLIPSE or at the Permit and License Center in the Municipal Services Building (by appointment).
- Review time limits
- Applications without plans are usually processed the same day in person or within 5 business days online; all others within 20 business days, and each resubmission within another 20 business days. Some work types can get accelerated review for an added fee. Permits must be picked up within 60 days of notice.
- Private review
- Accelerated (paid) review is offered for some work types; third-party review is not confirmed.
Where to read the codes, and who to ask
- City building codes (Title 4)
- Code Bulletin B-2501: Implementation of 2021 International Codes
- 2021 I-Code transition materials
- Start Right guide to permits and licenses (June 2026)
- eCLIPSE permit and license portal
- Department of Licenses and Inspections (L&I)Administers Title 4, issues permits and licenses contractors and trades
- Pennsylvania Department of Labor and IndustryAdopts the statewide UCC; elevators and accessibility
Not found yet
- The text of the local ordinance adopting the 2021 codes (described in L&I's April 2026 narrative) is not confirmed.
- Philadelphia Property Maintenance Code edition, local floodplain rules, green building rules and sprinkler rules for houses are not confirmed.
- Design values (wind, snow, frost) were not confirmed.
- Effective date of the 2018 IFC as the city fire code was not found.