Wisconsin
Wisconsin's codes are statewide rules of the Department of Safety and Professional Services (DSPS) in the SPS chapters of the Administrative Code. Public buildings, places of employment and apartment buildings of three or more units follow the Commercial Building Code (2021 IBC and related I-codes since September 1, 2025); one- and two-family dwellings follow the state's own Uniform Dwelling Code, which municipalities must adopt as written. DSPS or delegated municipalities review plans; municipalities issue permits.
20 codes are in force here, 17 of them checked at the source, and this page was last updated November 19, 2026.
Codes in force
BuildingWisconsin Commercial Building Code (SPS 361 to 366)September 1, 2025
Applies toAll public buildings and places of employment, including apartment buildings of three or more units. One- and two-family dwellings follow the Uniform Dwelling Code.
Based on, and how far it reachesIBC, 2021 edition.Applies across the state, and local governments enforce it as written.
Local changesAdopted by CR 23-007 with Wisconsin modifications; IBC storm shelter sections 423.4 and 423.5 are not included; Wisconsin roof snow load provisions in SPS 362.1608.
Adopted byWisconsin Department of Safety and Professional Services, Division of Industry Services.In force since September 1, 2025.
HousesWisconsin Uniform Dwelling Code (SPS 320 to 325)
Applies toOne- and two-family dwellings, including modular homes and the installation of manufactured homes. Municipalities that enforce it must adopt it in its entirety and may not add requirements within its scope unless DSPS approves.
Based on, and how far it reachesThe state's own code (SPS 320 to 325).Applies across the state, and local governments enforce it as written.
Local changesWisconsin's own code, in effect since June 1, 1980; latest amendments effective June 1, 2022. Footings at least 48 inches deep; roof loads from a state zone map; wind design 20 psf or ASCE 7-05.
Adopted byDSPS; municipalities, counties or certified UDC inspection agencies enforce.
Existing buildingsWisconsin Commercial Building Code, existing buildings (SPS 366)September 1, 2025
Applies toAlterations, additions and changes of occupancy of public buildings and places of employment.
Based on, and how far it reachesIEBC, 2021 edition.Applies across the state, and local governments enforce it as written.
Local changesWisconsin modifications in SPS 366.
Adopted byDSPS.In force since September 1, 2025.
Energy, housesUniform Dwelling Code energy conservation (SPS 322)January 1, 2016
Applies toOne- and two-family dwellings.
Based on, and how far it reachesIECC, 2009 edition.Applies across the state, and local governments enforce it as written.
Local changesWisconsin's own chapter created April 1, 2009 and amended January 1, 2016; the US Department of Energy rates it as equivalent to the 2009 IECC.
Adopted byDSPS.In force since January 1, 2016.
Energy, other buildingsWisconsin Commercial Building Code, energy conservation (SPS 363)September 1, 2025
Applies toPublic buildings, places of employment and apartment buildings of three or more units.
Based on, and how far it reachesIECC / ASHRAE 90.1 (2021 IECC; ASHRAE 90.1-2019).Applies across the state, and local governments enforce it as written.
Local changesWisconsin modifications; some IECC sections (for example C403.2.3 item 4 and parts of C404.6) are not included. DOE lists November 1, 2025 as its effective date; the code history shows September 1, 2025.
Adopted byDSPS.In force since September 1, 2025.
FireFire Prevention (SPS 314)
Applies toUse, operation and maintenance of public buildings and places of employment. Building design requirements in NFPA 1 and its referenced codes are excluded; design follows the Commercial Building Code. Municipalities may adopt an alternate model fire code under SPS 314.001 (2).
Based on, and how far it reachesNFPA 1, 2012 edition.Applies across the state, and local governments enforce it as written.
Local changesWisconsin modifications; last amended September 1, 2025.
Adopted byDSPS; local fire departments inspect.
PlumbingWisconsin Uniform Plumbing Code (SPS 381 to 387)September 1, 2026
Applies toPlumbing, private onsite wastewater systems and related work in all buildings, dwellings included.
Based on, and how far it reachesThe state's own code (SPS 381 to 387).Applies across the state, and local governments enforce it as written.
Local changesWisconsin's own code; latest amendments effective September 1, 2026.
Adopted byDSPS.In force since September 1, 2026.
MechanicalWisconsin Commercial Building Code, HVAC (SPS 364)September 1, 2025
Applies toHeating, ventilating and air conditioning in public buildings and places of employment; HVAC plans need approval before installation.
Based on, and how far it reachesIMC, 2021 edition.Applies across the state, and local governments enforce it as written.
Adopted byDSPS.In force since September 1, 2025.
Fuel gasWisconsin Commercial Building Code, fuel gas appliances (SPS 365)September 1, 2025
Applies toFuel gas piping and appliances in public buildings and places of employment.
Based on, and how far it reachesIFGC, 2021 edition.Applies across the state, and local governments enforce it as written.
Local changesSPS 365.0501 (4) requires plastic venting materials for fuel-fired equipment to meet UL 1738.
Adopted byDSPS.In force since September 1, 2025.
ElectricalWisconsin Electrical Code (SPS 316)September 1, 2026
Applies toElectrical installations in all buildings; permitting and inspection of new one- and two-family dwellings is under the UDC (SPS 320).
Based on, and how far it reachesNFPA 70, 2023 edition.Applies across the state, and local governments enforce it as written.
Local changesIncorporates the 2023 NEC with all Tentative Interim Amendments and errata issued before January 1, 2025, with Wisconsin modifications (CR 26-016).
Adopted byDSPS.In force since September 1, 2026.
AccessibilityAccessibility in the Wisconsin Commercial Building Code (SPS 362)September 1, 2025
Applies toPublic buildings, places of employment and multifamily buildings, through IBC Chapter 11 and ICC A117.1 with Wisconsin modifications.
Based on, and how far it reachesIBC Chapter 11 / ICC A117.1, 2021 edition.Applies across the state, and local governments enforce it as written.
Local changesWisconsin modifications in SPS 362.
Adopted byDSPS.In force since September 1, 2025.
Elevators and escalatorsElevators, Escalators and Lifting Devices (SPS 318)June 1, 2020
Applies toElevators, escalators and lifts, with Wisconsin changes to ASME A17.1-2016/CSA B44-16.
Based on, and how far it reachesASME A17.1, 2016 edition.Applies across the state, and local governments enforce it as written.
Adopted byDSPS; third-party inspection processing allowed.In force since June 1, 2020.
Pools and spasDesign, Construction, Maintenance and Operation of Public Swimming Pools (SPS 390)March 1, 2009
Applies toPublic swimming pools, whirlpools and water attractions, including pools at motels, schools, clubs and housing serving three or more residences; plan review by DSPS.
Based on, and how far it reachesThe state's own code (SPS 390).Applies across the state, and local governments enforce it as written.
Adopted byDSPS.In force since March 1, 2009.
Property maintenanceLocal property maintenance ordinances
Applies toNot part of the state codes; cities adopt their own.
Based on, and how far it reachesIPMC; the edition varies by city.Each city or county chooses whether to adopt it, and which edition.
Adopted byCities, villages and towns.
Sprinkler rules for housesUniform Dwelling Code, automatic fire sprinklers (SPS 321.095)
Applies toThe UDC does not require sprinklers in one- and two-family dwellings; where installed, design, installation, testing and maintenance must meet NFPA 13D.
Based on, and how far it reachesThe state's own code (SPS 321.095).Applies across the state, and local governments enforce it as written.
Adopted byDSPS.
Manufactured homesInstallation of manufactured homes under the Uniform Dwelling Code
Applies toInstallation of manufactured homes needs a UDC permit and inspection; DSPS licenses manufacturers, dealers, salespersons and installers. Manufactured home communities are licensed by DSPS or delegated counties.
Based on, and how far it reachesHUD 24 CFR 3280 (SPS 321 subchapter XI).Applies across the state, and local governments enforce it as written.
Adopted byDSPS.
Modular and factory-built buildingsModular Dwellings program
Applies toFactory-built one- and two-family dwellings: manufacturers are approved by DSPS with a compliance assurance manual reviewed by a third-party agency and report homes shipped monthly. Factory-built commercial and multifamily units carry a Wisconsin insignia under SPS 361.
Based on, and how far it reachesThe state's own code (SPS 320 to 325).Applies across the state, and local governments enforce it as written.
Adopted byDSPS.
Flood rules beyond the federal minimumWisconsin's Floodplain Management Program (NR 116)
Applies toMunicipal floodplain zoning under DNR rules. The flood protection elevation is 2 feet above the regional flood elevation; homes in the floodfringe must be on fill with the lowest floor (excluding basement or crawlway) at or above it, and any basement floor at or above the regional flood elevation and floodproofed to the flood protection elevation.
Based on, and how far it reachesThe state's own code (NR 116).A minimum across the state that local governments may add to.
Local changesTwo feet of freeboard.
Adopted byWisconsin Department of Natural Resources; municipal zoning.
Structural loadsStructural design in the Commercial Building Code (SPS 362, IBC Chapter 16) and the UDCSeptember 1, 2025
Applies toCommercial buildings use IBC Chapter 16 with Wisconsin roof snow load rules in SPS 362.1608. Dwellings use the UDC zone map for roof loads and 20 psf wind pressure or ASCE 7-05.
Based on, and how far it reachesASCE 7, 2016 edition.Applies across the state, and local governments enforce it as written.
Adopted byDSPS.In force since September 1, 2025.
Boilers and pressure vesselsBoilers and Pressure Vessels (SPS 341)June 1, 2012
Applies toBoilers and pressure vessels: ASME Boiler and Pressure Vessel Code 2010 and National Board Inspection Code 2011, with Wisconsin rules.
Based on, and how far it reachesASME BPVC, 2010 edition.Applies across the state, and local governments enforce it as written.
Adopted byDSPS.In force since June 1, 2012.
Not adopted here, or not found yet
Life safetyNFPA 101 design requirements not adoptedNo code of this kind is adopted
Applies toSPS 314 states that design requirements reached through NFPA 1, including those of NFPA 101, are not part of the state fire code except as it specifically provides. Health care facilities meet the federal CMS edition.
Based on, and how far it reachesNFPA 101.
Adopted byDSPS.
Green building and stretch codesNo statewide green or stretch codeNo code of this kind is adopted
Applies toNo IgCC or stretch energy code is adopted; the UDC bars local additions within its scope.
Adopted byDSPS.
Wildland-urban interfaceNo wildland-urban interface codeNo code of this kind is adopted
Applies toNo IWUIC adoption found.
Adopted byDSPS.
Who designs, seals and builds
- Architect
- Public buildings and places of employment must be designed by an architect or engineer, except as allowed by ss. 443.14 and 443.15, Stats. A project does not need supervision by a Wisconsin-registered architect or engineer if the building is under 50,000 cubic feet of total volume (or an addition keeps it under that). Plans submitted for review must be signed and sealed under ch. 443 and A-E 2.02. One- and two-family dwellings under the UDC are outside these rules.Wis. Stat. ch. 443; Wis. Admin. Code SPS 361.30, 361.31; A-E 2.02Checked at the source
- Engineer
- Electrical, fire protection, HVAC and plumbing systems for public buildings must be designed by an architect, engineer or registered designer of engineering systems (ch. 443 exceptions apply). Sprinkler documents may instead be signed by a licensed automatic fire sprinkler contractor. Structural calculations and energy calculations submitted for review must be signed, sealed and dated.Wis. Stat. ch. 443; Wis. Admin. Code SPS 361.30 (2) (b), 361.31Checked at the source
- Contractor
- DSPS credentials builders and trades: a Dwelling Contractor and Dwelling Contractor Qualifier credential is needed to take out UDC permits; electrical contractors and electricians, plumbers, HVAC contractors and qualifiers, elevator contractors and mechanics, and automatic fire sprinkler contractors and fitters are licensed. No state license for commercial general contractors was found.Wis. Stat. ch. 101 and 145; Wis. Admin. Code SPS 305Checked at the source
Design loads and hazards
- Wind
- Dwellings: 20 psf horizontal and uplift pressure or ASCE 7-05 (SPS 321.02). Commercial: IBC Chapter 16 (ASCE 7-16 with the 2021 IBC).
- Snow
- Dwellings: roof snow loads from the UDC zone map (Figure 321.02). Commercial: Wisconsin roof snow load provisions in SPS 362.1608 with ground snow from the IBC map.
- Seismic
- Not confirmed; Wisconsin is a low seismic hazard area.
- Frost depth
- Dwelling footings must be below frost penetration or at least 48 inches below adjacent grade, whichever is deeper, unless frost-protected shallow foundations are used (SPS 321.16).
- Flood
- NR 116: flood protection elevation is 2 feet above the regional flood elevation; residential lowest floors in the floodfringe must be at or above it.
- Other hazards
- No state storm shelter mandate: IBC sections 423.4 and 423.5 are excluded.
Permits
- Who issues them
- Commercial: DSPS, or a municipality delegated for buildings of that size, reviews plans for buildings of 25,000 cubic feet or more, any school, high-hazard occupancy or residential building of three or more units; DSPS does not issue commercial building permits, municipalities do. Dwellings: delegated municipalities or, where none, DSPS issue the Wisconsin uniform building permit; municipalities may enforce through their own inspectors, jointly, by contract with certified UDC inspectors or agencies, or through another municipality.
- Review time limits
- Commercial plan review decisions within 15 business days; permission to start footings and foundations within 3 business days. UDC permit applications must be approved or denied within 10 business days of a complete application.
- Private review
- Municipalities may contract certified UDC inspectors or independent inspection agencies; DSPS processes third-party elevator inspections; modular dwelling plans are reviewed by third-party agencies before DSPS.
Cities and counties with their own codes
Where to read the codes, and who to ask
- Wis. Admin. Code SPS 361 to 366 (Commercial Building Code)
- Wis. Admin. Code SPS 320 to 325 (Uniform Dwelling Code)
- Wis. Admin. Code SPS 316 (Electrical Code)
- DSPS Commercial Buildings program (plan review, code inserts)
- DSPS UDC program (permits, inspections)
- Wis. Admin. Code NR 116 (floodplain management)
- Wisconsin codes on ICC Digital Codes
- US DOE energy code status: Wisconsin
- Wisconsin Department of Safety and Professional Services, Division of Industry ServicesWrites and enforces the state building, dwelling, plumbing, electrical, fire, elevator, boiler and pool codes; plan review; credentials
- Wisconsin Department of Natural Resources, Floodplain ManagementFloodplain rules (NR 116)
- eSLA (DSPS electronic licensing and plan submittal)Plan review and permit applications
Not found yet
- UDC roof snow load zone values (Figure 321.02 is an image) were not confirmed.
- Whether state law bars local governments from requiring sprinklers in one- and two-family dwellings: not confirmed; the UDC itself does not require them.
- Effective date of the NFPA 1-2012 adoption in SPS 314 not confirmed (last amended September 1, 2025).
- Exemptions in Wis. Stat. 443.14 and 443.15 for designing small buildings were not confirmed.
- Boiler code still cites ASME 2010 and NBIC 2011; any pending update not confirmed.
- Local agencies' delegated plan review limits (Milwaukee, Madison) not confirmed.